Indications and outcomes of the MitraClip G4 device with controlled gripper actuation system.
Nishiura, Naoki; Kubo, Shunsuke; Fujita, Mikitaka; Mushiake, Kazunori; Ono, Sachiyo; Osakada, Kohei; Maruo, Takeshi; Kadota, Kazushige.
Afiliación
  • Nishiura N; Department of Cardiovascular Medicine, Kurashiki Central Hospital, 1-1-1, Miwa, Kurashiki, Okayama, Japan.
  • Kubo S; Department of Cardiovascular Medicine, Kurashiki Central Hospital, 1-1-1, Miwa, Kurashiki, Okayama, Japan. sk12750@kchnet.or.jp.
  • Fujita M; Department of Cardiovascular Medicine, Kurashiki Central Hospital, 1-1-1, Miwa, Kurashiki, Okayama, Japan.
  • Mushiake K; Department of Cardiovascular Medicine, Kurashiki Central Hospital, 1-1-1, Miwa, Kurashiki, Okayama, Japan.
  • Ono S; Department of Cardiovascular Medicine, Kurashiki Central Hospital, 1-1-1, Miwa, Kurashiki, Okayama, Japan.
  • Osakada K; Department of Cardiovascular Medicine, Kurashiki Central Hospital, 1-1-1, Miwa, Kurashiki, Okayama, Japan.
  • Maruo T; Department of Cardiovascular Medicine, Kurashiki Central Hospital, 1-1-1, Miwa, Kurashiki, Okayama, Japan.
  • Kadota K; Department of Cardiovascular Medicine, Kurashiki Central Hospital, 1-1-1, Miwa, Kurashiki, Okayama, Japan.
Cardiovasc Interv Ther ; 39(4): 468-478, 2024 Oct.
Article en En | MEDLINE | ID: mdl-38833119
ABSTRACT
The MitraClip G4 device has controlled gripper actuation (CGA) system, which allows the anterior and posterior grippers operate separately in transcatheter edge-to-edge repair (TEER). We investigated the indications and outcomes of the use of CGA system during TEER for significant mitral regurgitation (MR). We reviewed 158 patients undergoing TEER with MitraClip G4 from September 2020 to July 2023. The CGA indications were (1) for grasping and (2) for leaflet insertion confirmation. Leaflet grasping was completed with CGA in 18 patients (11 and 7 patients for grasping and leaflet insertion confirmation, respectively). Patients with flail leaflets or coaptation gap more frequently required CGA, indicating more complex mitral valve anatomy. The procedural success and adverse event rates (death, leaflet tear and single leaflet device attachment) were not different between the CGA and non-CGA groups. In patients requiring CGA, single leaflet device attachment was observed in 1 patient and leaflet tear in 1 patient during follow-up. In these two cases, CGA was required for grasping, and the clip was moved over a large distance (6.5 and 12.4 mm, respectively). In patients who had undergone CGA for confirmation, no device-related adverse event or MR recurrence was noted. In patients with complex mitral valve anatomy, CGA may be a safe and effective method for confirming leaflet insertion. It should be noted that when using CGA for leaflet grasping, especially when the clip is moved significantly, attention should be paid to leaflet adverse events.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Mitral / Insuficiencia de la Válvula Mitral Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Cardiovasc Interv Ther Año: 2024 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Mitral / Insuficiencia de la Válvula Mitral Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Cardiovasc Interv Ther Año: 2024 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Japón