Your browser doesn't support javascript.
loading
Design and evaluation of the OmniSuit: A passive occupational exoskeleton for back and shoulder support.
van Sluijs, Rachel; Scholtysik, Tamina; Brunner, Annina; Kuoni, Laura; Bee, Dario; Kos, Melanie; Bartenbach, Volker; Lambercy, Olivier.
Afiliación
  • van Sluijs R; Auxivo AG, Sonnenbergstrasse 74, Schwerzenbach, 8603, Zürich, Switzerland.
  • Scholtysik T; Rehabilitation Engineering Laboratory, ETH Zürich, Gloriastrasse 37/39, Zürich, 8092, Zürich, Switzerland.
  • Brunner A; Auxivo AG, Sonnenbergstrasse 74, Schwerzenbach, 8603, Zürich, Switzerland.
  • Kuoni L; Rehabilitation Engineering Laboratory, ETH Zürich, Gloriastrasse 37/39, Zürich, 8092, Zürich, Switzerland.
  • Bee D; Auxivo AG, Sonnenbergstrasse 74, Schwerzenbach, 8603, Zürich, Switzerland.
  • Kos M; Auxivo AG, Sonnenbergstrasse 74, Schwerzenbach, 8603, Zürich, Switzerland.
  • Bartenbach V; Auxivo AG, Sonnenbergstrasse 74, Schwerzenbach, 8603, Zürich, Switzerland.
  • Lambercy O; Rehabilitation Engineering Laboratory, ETH Zürich, Gloriastrasse 37/39, Zürich, 8092, Zürich, Switzerland. Electronic address: relab.publications@hest.ethz.ch.
Appl Ergon ; 120: 104332, 2024 Oct.
Article en En | MEDLINE | ID: mdl-38876001
ABSTRACT
Many physically straining occupations involve lifting movements over the full-vertical range of motion, which over time may lead to the development of musculoskeletal injuries. To address this, occupational exoskeletons can be designed to provide meaningful support to the back and shoulders during lifting movements. This paper introduces the main functional design features of the OmniSuit, a novel passive occupational exoskeleton. We present the technical and biomechanical considerations for the expected support level, as well as an evaluation of the physiological benefit and usability of the exoskeleton in a sample of 31 healthy volunteers performing physically demanding tasks in a laboratory setting. The OmniSuit exoskeleton significantly reduced Deltoid, Trapezius and Erector Spinae muscle activity between 4.1%MVC and 15.7%MVC when lifting a 2.5kg weight above shoulder level (p<0.001), corresponding to a reduction of up to 49.1% compared to without exoskeleton. A position-dependent reduction of Erector Spinae muscle activity was observed (p<0.001), with reductions ranging between 4.6%MVC and 14.0%MVC during leaning and squatting, corresponding to a reduction up to 41.5% compared to without exoskeleton. The measured muscular support and the predicted support torque based on the biomechanical model were found to show a similar profile for those phases of the movement which are most straining to the shoulder and back muscles. Participants reported experiencing good device usability and minimal discomfort (<1/10) in the shoulder and back during task execution with exoskeleton support. These first results validate that the considered biomechanical model helped design an ergonomic and efficient exoskeleton, and confirm the potential of such wearable assistive devices to provide support over multiple joints during physically demanding tasks.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hombro / Rango del Movimiento Articular / Electromiografía / Diseño de Equipo / Dispositivo Exoesqueleto Límite: Adult / Female / Humans / Male Idioma: En Revista: Appl Ergon Año: 2024 Tipo del documento: Article País de afiliación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hombro / Rango del Movimiento Articular / Electromiografía / Diseño de Equipo / Dispositivo Exoesqueleto Límite: Adult / Female / Humans / Male Idioma: En Revista: Appl Ergon Año: 2024 Tipo del documento: Article País de afiliación: Suiza