Myocardial performance imaging for the early identification of cardiac dysfunction in neonates with sepsis.
Int J Cardiovasc Imaging
; 40(7): 1435-1444, 2024 Jul.
Article
en En
| MEDLINE
| ID: mdl-38907854
ABSTRACT
PURPOSE:
The assessment of cardiac performance in septic new-borns is crucial for detecting hemodynamic instability and predicting outcome. The aim of the study is to assess myocardial performance in neonates with sepsis for the early identification of cardiac dysfunction. PATIENTS ANDMETHODS:
A case control study was carried out from September 2022 to May 2023 at the Neonatal Intensive care unit, Kasturba Medical College, Manipal. A total of 68 neonates were included in the study, with 33 females and 35 males. The study population was further subdivided into 3 groups namely preterm septic neonates (n = 21), term septic neonates (n = 10) and non-septic healthy controls (n = 37). The cardiac structure and function were assessed using conventional method, Tissue Doppler imaging (Sm) and speckle tracking echocardiography (GLS). The study was approved by the Institutional Ethics Committee at Kasturba Medical College, Manipal (approval number IEC 90/2022). The CTRI registration number for the study is CTRI/2022/09/045437 and was approved on September 12, 2022. Prior to the neonate's enrolment, informed consent was obtained from their mothers or legal guardians.RESULTS:
Out of the total 68 neonates, 31 were cases and 37 were controls which included 33 females and 35 males. LV systolic function was not statistically significant between cases and controls. E/A ratio of the mitral valve was significantly lower in septic newborns than in healthy neonates. (1.01 ± 0.35 vs 1.18 ± 0.31, p < 0.05) preterm neonates showed significantly lower Lateral E' and RV E' velocities than term neonates. TAPSE was significantly lower in septic preterm neonates. (8.61 ± 1.28 vs. 10.7 ± 2.11, p < 0.05) No significant difference was noted in the Myocardial Performance Index between septic neonates and healthy neonates. LV Global Longitudinal Strain was slightly lower in preterm septic neonates than in term neonates with sepsis.CONCLUSION:
Septic newborns are associated with LV diastolic dysfunction, RV systolic dysfunction and substantially higher pulmonary systolic pressures.Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Valor Predictivo de las Pruebas
/
Función Ventricular Izquierda
/
Diagnóstico Precoz
/
Sepsis Neonatal
Límite:
Female
/
Humans
/
Male
/
Newborn
Idioma:
En
Revista:
Int J Cardiovasc Imaging
Asunto de la revista:
DIAGNOSTICO POR IMAGEM
Año:
2024
Tipo del documento:
Article
País de afiliación:
India
Pais de publicación:
Estados Unidos