Clinical results of two different three-dimensional plate types for the treatment of mandibular angle fractures: a retrospective analysis.
Pfister, Jelena; Shazwani, Farah Nur; Müller, Martin; Burkhard, John-Patrik.
Afiliación
  • Pfister J; Department of Cranio-Maxillofacial Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, CH-3010, Switzerland.
  • Shazwani FN; Department of Cranio-Maxillofacial Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, CH-3010, Switzerland.
  • Müller M; Department of Emergency Medicine, Inselspital, University Hospital Bern, University of Bern, Bern, 3010, Switzerland.
  • Burkhard JP; Limmat Cleft and Craniofacial Centre, Zurich, CH-8005, Switzerland. jp_burkhard@me.com.
Oral Maxillofac Surg ; 2024 Jun 26.
Article en En | MEDLINE | ID: mdl-38918316
ABSTRACT

OBJECTIVES:

The purpose of this study was to compare two different designs of three-dimensional osteosynthesis plates for their suitability in the treatment of mandibular angle fractures in terms of sufficient fracture healing and concomitant complications. MATERIALS AND

METHODS:

Retrospectively a total of 54 patients with 56 mandibular angle fractures were evaluated. Two different types of three-dimensional plates from the Medartis Trilock system were analyzed (A) Square design plate (☐-plate) with a thickness of 1.0 mm, and (B) triangular-shaped 3D-plate (△-plate) with a thickness of 1.3 mm. Patient demographics, fracture mechanism and intraoperative details were recorded during an average follow-up period of 1 year.

RESULTS:

The utilization of △-plates was observed to entail a considerably lengthier surgical time in contrast to ☐-plate systems (P = 0.037). The application of △-plate showed a tendency of higher incidence of major complications than ☐-plate (P = 0.06), as evidenced by the occurrence of non-union in 2 out of 22 cases, resulting in higher surgical revision rate for △-plate (P = 0.027).

CONCLUSION:

Sufficient treatment of mandibular angle fractures is feasible by using 1.0 mm thick, square shaped three-dimensional plate systems. The use of thicker three-dimensional osteosynthesis plates seems to significantly increase the operating time and complication rates, whereby the geometry of the plate seems to have an influence. CLINICAL RELEVANCE The plate design could have an impact on treatment outcomes of mandibular angle fractures. TRIAL REGISTRATION NUMBER Not applicable.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Oral Maxillofac Surg Asunto de la revista: ODONTOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Oral Maxillofac Surg Asunto de la revista: ODONTOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Suiza