Your browser doesn't support javascript.
loading
Assessment of Thermal and Mechanical Indices as Acoustic Output Parameters Used in Obstetric Ultrasound in Saudi Arabia.
Gareeballah, Awadia; Alharbi, Wafa Ghazai; Alharbi, Taif Sami; Alhejaili, Rodina Mohammed; Maashi, Nouf Ahmed; Al-Ahmadi, Fadwa Mohammed; Alshoabi, Sultan Abdulwadoud; Gameraddin, Moawia; Elzaki, Maisa; Alsharif, Walaa; Abouraida, Raga Ahmed; Adam, Mohammed; Alzain, Amal F H.
Afiliación
  • Gareeballah A; Department of Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Al-Madinah Al-Munawwarah, Saudi Arabia.
  • Alharbi WG; Department of Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Al-Madinah Al-Munawwarah, Saudi Arabia.
  • Alharbi TS; Department of Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Al-Madinah Al-Munawwarah, Saudi Arabia.
  • Alhejaili RM; Department of Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Al-Madinah Al-Munawwarah, Saudi Arabia.
  • Maashi NA; Department of Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Al-Madinah Al-Munawwarah, Saudi Arabia.
  • Al-Ahmadi FM; King Salman Medical City- Maternity and Children's Hospital in Al-Madina Al-Munawwarah, Saudi Arabia.
  • Alshoabi SA; Department of Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Al-Madinah Al-Munawwarah, Saudi Arabia.
  • Gameraddin M; Department of Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Al-Madinah Al-Munawwarah, Saudi Arabia.
  • Elzaki M; Department of Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Al-Madinah Al-Munawwarah, Saudi Arabia.
  • Alsharif W; Department of Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Al-Madinah Al-Munawwarah, Saudi Arabia.
  • Abouraida RA; Department of Radiology Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Asir, Saudi Arabia.
  • Adam M; King Khalid University College of Medical Applied Sciences, Department of Diagnostic Radiology Sciences Abha Saudi Arabia.
  • Alzain AFH; Department of Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Al-Madinah Al-Munawwarah, Saudi Arabia.
Curr Med Imaging ; 20: e15734056312545, 2024.
Article en En | MEDLINE | ID: mdl-38918981
ABSTRACT

BACKGROUND:

Patient safety is paramount in ultrasound procedures, particularly in obstetric ultrasounds involving both the mother and fetus. The thermal and mechanical indices (TI and MI) serve as crucial indicators of the acoustic output during ultrasound. Clinicians and specialists must know these indices and ensure they are within safe ranges. This study aimed to assess the parameters of acoustic output power employed in obstetric ultrasound (thermal and mechanical index).

METHODOLOGY:

A cross-sectional observational study conducted at Maternity and Children's Hospital in Al-Madina Al-Munawwarah, the data was collected from obstetric scanning of 411 pregnant females using a data collection sheet including gravida and women's age, gestational age, scan mode, scan time, and thermal and mechanical index (TI and MI) values.

RESULTS:

The study found that there were significant differences in safety indices measurement between different modes; in Pulsed Doppler, mean Thermal Index Bone (TIb) had the highest value (1.60±0.40), and the Mechanical Index (MI) was the lowest (0.68±0.33). There were insignificant differences in safety indices values in different modes in different trimesters. The thermal indices of soft tissue and bony structure (TIs and TIb) of brightness mode (B-mode) were constant in all trimesters, but the MI in the first trimester was lower than in the other trimesters.

CONCLUSION:

This study found significant differences in TIs, TIb, and MI in different modes of obstetric ultrasound. Pulsed Doppler ultrasonography had the highest TIb value and a lower MI value. The ultrasound acoustic exposure output parameters were within the standard's recommended limit.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ultrasonografía Prenatal Límite: Adult / Female / Humans / Pregnancy País/Región como asunto: Asia Idioma: En Revista: Curr Med Imaging Año: 2024 Tipo del documento: Article País de afiliación: Arabia Saudita Pais de publicación: Emiratos Árabes Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ultrasonografía Prenatal Límite: Adult / Female / Humans / Pregnancy País/Región como asunto: Asia Idioma: En Revista: Curr Med Imaging Año: 2024 Tipo del documento: Article País de afiliación: Arabia Saudita Pais de publicación: Emiratos Árabes Unidos