Your browser doesn't support javascript.
loading
Simultaneous Electrochemical Detection of Dopamine and Tryptophan Using 3D Goethite-Spongin Composites.
Falahi, Sedigheh; Kubiak, Anita; Voronkina, Alona; Ehrlich, Hermann; Joseph, Yvonne; Rahimi, Parvaneh.
Afiliación
  • Falahi S; Institute of Nanoscale and Biobased Materials, Faculty of Materials Science and Material Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany.
  • Kubiak A; Faculty of Chemistry, Adam Mickiewicz University, Uniwersytetu Poznanskiego 8, 61-614 Poznan, Poland.
  • Voronkina A; Center of Advanced Technology, Adam Mickiewicz University, Uniwersytetu Poznanskiego 10, 61-614 Poznan, Poland.
  • Ehrlich H; Department of Pharmacy, National Pirogov Memorial Medical University, Vinnytsya, Pyrogov Street 56, 21018 Vinnytsia, Ukraine.
  • Joseph Y; Faculty of Chemistry, Adam Mickiewicz University, Uniwersytetu Poznanskiego 8, 61-614 Poznan, Poland.
  • Rahimi P; Faculty of Chemical Technology, Institute of Chemical Technology and Engineering, Poznan University of Technology, Berdychowo 4, 60-965 Poznan, Poland.
Biomimetics (Basel) ; 9(6)2024 Jun 14.
Article en En | MEDLINE | ID: mdl-38921236
ABSTRACT
In this study, a facile approach for simultaneous determination of dopamine (DA) and tryptophan (TRP) using a 3D goethite-spongin-modified carbon paste electrode is reported. The prepared electrode exhibited excellent electrochemical catalytic activity towards DA and TRP oxidation. The electrochemical sensing of the modified electrode was investigated using cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy. Through differential pulse voltammetry analysis, two well-separated oxidation peaks were observed at 28 and 77 mV, corresponding to the oxidation of DA and TRP at the working electrode, with a large peak separation of up to 490 mV. DA and TRP were determined both individually and simultaneously in their dualistic mixture. As a result, the anodic peak currents and the concentrations of DA and TRP were found to exhibit linearity within the ranges of 4-246 µM for DA and 2 to 150 µM for TRP. The detection limits (S/N = 3) as low as 1.9 µM and 0.37 µM were achieved for DA and TRP, respectively. The proposed sensor was successfully applied to the simultaneous determination of DA and TRP in human urine samples with satisfactory recoveries (101% to 116%).
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Biomimetics (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Biomimetics (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Alemania
...