Your browser doesn't support javascript.
loading
[Structural design and evaluation of bone remodeling effect of fracture internal fixation implants with time-varying stiffness].
Sun, Hao; Ding, Xiaohong; Xu, Shipeng; Duan, Pengyun; Xiong, Min; Zhang, Heng.
Afiliación
  • Sun H; School of Mechanical Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
  • Ding X; School of Mechanical Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
  • Xu S; Shanghai Special Equipment Supervision and Inspection Technology Research Institute, Shanghai 200062, P. R. China.
  • Duan P; School of Mechanical Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
  • Xiong M; School of Mechanical Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
  • Zhang H; School of Mechanical Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(3): 595-603, 2024 Jun 25.
Article en Zh | MEDLINE | ID: mdl-38932547
ABSTRACT
The stiffness of an ideal fracture internal fixation implant should have a time-varying performance, so that the fracture can generate reasonable mechanical stimulation at different healing stages, and biodegradable materials meet this performance. A topology optimization design method for composite structures of fracture internal fixation implants with time-varying stiffness is proposed, considering the time-dependent degradation process of materials. Using relative density and degradation residual rate to describe the distribution and degradation state of two materials with different degradation rates and elastic modulus, a coupled mathematical model of degradation simulation mechanical analysis was established. Biomaterial composite structures were designed based on variable density method to exhibit time-varying stiffness characteristics. Taking the bone plate used for the treatment of tibial fractures as an example, a composite structure bone plate with time-varying stiffness characteristics was designed using the proposed method. The optimization results showed that material 1 with high stiffness formed a columnar support structure, while material 2 with low stiffness was distributed at the degradation boundary and inside. Using a bone remodeling simulation model, the optimized bone plates were evaluated. After 11 months of remodeling, the average elastic modulus of callus using degradable time-varying stiffness plates, titanium alloy plates, and stainless steel plates were 8 634 MPa, 8 521 MPa, and 8 412 MPa, respectively, indicating that the use of degradable time-varying stiffness plates would result in better remodeling effects on the callus.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fracturas de la Tibia / Titanio / Placas Óseas / Remodelación Ósea / Módulo de Elasticidad / Fijación Interna de Fracturas Límite: Humans Idioma: Zh Revista: Sheng Wu Yi Xue Gong Cheng Xue Za Zhi / Sheng wu yi xue gong cheng xue za zhi Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article Pais de publicación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fracturas de la Tibia / Titanio / Placas Óseas / Remodelación Ósea / Módulo de Elasticidad / Fijación Interna de Fracturas Límite: Humans Idioma: Zh Revista: Sheng Wu Yi Xue Gong Cheng Xue Za Zhi / Sheng wu yi xue gong cheng xue za zhi Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article Pais de publicación: China