Your browser doesn't support javascript.
loading
Evaluation of Fine Needle Biopsy (FNB) for Endoscopic Ultrasound (EUS)-guided Tissue Acquisition of Pancreatic Masses to Negate the Need for Rapid On-site Evaluation: A Randomized Control Trial.
De Lusong, Mark Anthony A; Pajes, A Nico Nahar I.
Afiliación
  • De Lusong MAA; Division of Gastroenterology, Department of Medicine, College of Medicine and Philippine General Hospital, University of the Philippines Manila.
  • Pajes ANNI; Division of Gastroenterology, Department of Medicine, College of Medicine and Philippine General Hospital, University of the Philippines Manila.
Acta Med Philipp ; 58(1): 51-56, 2024.
Article en En | MEDLINE | ID: mdl-38939857
ABSTRACT
Background and

Objectives:

The benefits of rapid on-site evaluation (ROSE) of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid masses have not been convincingly shown in large, randomized trials. New equipment using EUS-guided fine needle biopsy (FNB) allows for more material to be acquired that may obviate the need for ROSE. This study aimed to evaluate if EUS-FNB without ROSE was non-inferior to EUS-FNA with ROSE in solid pancreatic masses (SPMs).

Methods:

Patients with SPMs requiring tissue sampling were randomly assigned to undergo either EUS-FNA with ROSE or EUS-FNB without ROSE. The touch-imprint cytology technique was used to perform ROSE. The primary endpoint was diagnostic accuracy and secondary endpoints were specimen quality, complication rates, and procedure time.

Results:

Seventy-eight patients were randomized and analyzed (39 EUS-FNA with ROSE and 39 EUS-FNB without ROSE). Non-significantly different diagnostic accuracies were noted in both groups (97% with ROSE and 100% without ROSE, P < 0.371). The bloodiness of histologic samples and complication rates were not significantly different between groups. A significantly shorter mean sampling procedural time was noted for EUS-FNB over EUS-FNA with ROSE (30.4 ± 10.4 vs 35.8 ± 9.8 minutes, P < .02).

Conclusions:

EUS-FNB demonstrated equal diagnostic accuracy with shorter procedure times in evaluating SPMs compared to EUS-FNA with ROSE. These new-generation FNB needles may obviate the need for ROSE.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Acta Med Philipp / Acta med. Philipp / Acta medica Philippina Año: 2024 Tipo del documento: Article Pais de publicación: Filipinas

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Acta Med Philipp / Acta med. Philipp / Acta medica Philippina Año: 2024 Tipo del documento: Article Pais de publicación: Filipinas