A novel artificial intelligence model for measuring fetal intracranial markers during the first trimester based on two-dimensional ultrasound image.
Sun, Lingling; Yu, Junxuan; Yao, Jiezhi; Cao, Yan; Sun, Naimin; Chen, Keqi; Lin, Yujia; Ji, Chunya; Zhang, Jun; Ling, Chen; Yang, Zhong; Pan, Qi; Yang, Ronghao; Yang, Xin; Ni, Dong; Yin, Linliang; Deng, Xuedong.
Afiliación
  • Sun L; Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China.
  • Yu J; National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, Guangdong, China.
  • Yao J; National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, Guangdong, China.
  • Cao Y; Shenzhen RayShape Medical Technology Co., Ltd, Shenzhen, Guangdong, China.
  • Sun N; Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China.
  • Chen K; Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China.
  • Lin Y; National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, Guangdong, China.
  • Ji C; Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China.
  • Zhang J; Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China.
  • Ling C; Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China.
  • Yang Z; Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China.
  • Pan Q; Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China.
  • Yang R; National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, Guangdong, China.
  • Yang X; National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, Guangdong, China.
  • Ni D; National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, Guangdong, China.
  • Yin L; Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China.
  • Deng X; Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China.
Article en En | MEDLINE | ID: mdl-38944698
ABSTRACT

OBJECTIVE:

To establish reference ranges of fetal intracranial markers during the first trimester and develop the first novel artificial intelligence (AI) model to measure key markers automatically.

METHODS:

This retrospective study used two-dimensional (2D) ultrasound images from 4233 singleton normal fetuses scanned at 11+0-13+6 weeks of gestation at the Affiliated Suzhou Hospital of Nanjing Medical University from January 2018 to July 2022. We analyzed 10 key markers in three important planes of the fetal head. Based on these, reference ranges of 10 fetal intracranial markers were established and an AI model was developed for automated marker measurement. AI and manual measurements were compared to evaluate differences, correlations, consistency, and time consumption based on mean error, Pearson correlation analysis, intraclass correlation coefficients (ICCs), and average measurement time.

RESULTS:

The results of AI and manual methods had strong consistency and correlation (all ICC values >0.75, all r values >0.75, and all P values <0.001). The average absolute error of both only ranged from 0.124 to 0.178 mm. AI achieved a 100% detection rate for abnormal cases. Additionally, the average measurement time of AI was only 0.49 s, which was more than 65 times faster than the manual measurement method.

CONCLUSION:

The present study first established the normal standard reference ranges of fetal intracranial markers based on a large Chinese population data set. Furthermore, the proposed AI model demonstrated its capability to measure multiple fetal intracranial markers automatically, serving as a highly effective tool to streamline sonographer tasks and mitigate manual measurement errors, which can be generalized to first-trimester scanning.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Int J Gynaecol Obstet Año: 2024 Tipo del documento: Article País de afiliación: China