Your browser doesn't support javascript.
loading
Preparation of cylindrical Chitosan/ß-Cyclodextrin/MIL-68(Al) foam column for solid-phase extraction of sulfonamides in water, urine, and milk.
Zhang, Yong; Wang, Jing; Liu, Fubin; Wang, Litao; Gao, Guihua.
Afiliación
  • Zhang Y; School of Pharmacy, Jining Medical University, No. 669, Xueyuan Road, Donggang District, Rizhao, Shandong Province, 276826, PR China.
  • Wang J; School of Pharmacy, Shandong University of Traditional Chinese Medicine, No. 4655, University Road, University Science Park, Changqing District, Jinan, Shandong Province, PR China.
  • Liu F; School of Pharmacy, Jining Medical University, No. 669, Xueyuan Road, Donggang District, Rizhao, Shandong Province, 276826, PR China.
  • Wang L; School of Pharmacy, Jining Medical University, No. 669, Xueyuan Road, Donggang District, Rizhao, Shandong Province, 276826, PR China. Electronic address: wanglilvtao@163.com.
  • Gao G; School of Pharmacy, Jining Medical University, No. 669, Xueyuan Road, Donggang District, Rizhao, Shandong Province, 276826, PR China. Electronic address: guihua526@163.com.
J Chromatogr A ; 1730: 465130, 2024 Aug 16.
Article en En | MEDLINE | ID: mdl-38955130
ABSTRACT
This study describes the preparation of a cylindrical polymer foam column termed Chitosan/ß-Cyclodextrin/MIL-68(Al) (CS/ß-CD/MIL-68(Al)). An ice template-freeze drying technique was employed to prepare the CS/ß-CD/MIL-68(Al) foam column by embedding MIL-68(Al) in a polymer matrix comprising cross-linked chitosan (CS) and ß-cyclodextrin (ß-CD). The cylindrical CS/ß-CD/MIL-68(Al) foam was subsequently inserted into a syringe to develop a solid phase extraction (SPE) device. Without the requirement for an external force, the sample solution passed easily through the SPE column thanks to the porous structure of the CS/ß-CD/MIL-68(Al) foam column. Moreover, the CS/ß-CD/MIL-68(Al) foam column was thought to be a superior absorbent for SPE since it included the adsorptive benefits of CS, ß-CD, and MIL-68(Al). The SPE was utilized in conjunction with high-performance liquid chromatography to analyze six sulfonamides found in milk, urine, and water. With matrix effects ranging from 80.49 % to 104.9 % with RSD values of 0.4-14.0 %, the method showed high recoveries ranging from 80.6 to 107.4 % for water samples, 93.4-105.2 % for urine, and 87.4-100.9 % for milk. It also demonstrated good linearity in the range of 10-258 ng·mL-1 with the limits of detection ranging from 1.88 to 2.58 ng·mL-1. The cylindrical CS/ß-CD/MIL-68(Al) foam column prepared in this work offered several advantages, including its simple fabrication, excellent water stability, absence of pollutants, biodegradability, and reusability. It is particularly well-suited for SPE. Furthermore, the developed SPE method, employing CS/ß-CD/MIL-68(Al) foam column, is straightforward and precise, and its benefits, including affordability, ease of preparation, lack of specialized equipment, and solvent economy, underline its broad applicability for the pretreatment of aqueous samples.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Sulfonamidas / Leche / Beta-Ciclodextrinas / Quitosano / Extracción en Fase Sólida / Límite de Detección / Estructuras Metalorgánicas Límite: Animals / Humans Idioma: En Revista: J Chromatogr A Año: 2024 Tipo del documento: Article Pais de publicación: HOLANDA / HOLLAND / NETHERLANDS / NL / PAISES BAJOS / THE NETHERLANDS

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Sulfonamidas / Leche / Beta-Ciclodextrinas / Quitosano / Extracción en Fase Sólida / Límite de Detección / Estructuras Metalorgánicas Límite: Animals / Humans Idioma: En Revista: J Chromatogr A Año: 2024 Tipo del documento: Article Pais de publicación: HOLANDA / HOLLAND / NETHERLANDS / NL / PAISES BAJOS / THE NETHERLANDS