Your browser doesn't support javascript.
loading
Electric field and SAR reduction in high-impedance RF arrays by using high permittivity materials for 7T MR imaging.
Bhosale, Aditya A; Zhao, Yunkun; Zhang, Xiaoliang.
Afiliación
  • Bhosale AA; Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States of America.
  • Zhao Y; Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States of America.
  • Zhang X; Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States of America.
PLoS One ; 19(7): e0305464, 2024.
Article en En | MEDLINE | ID: mdl-38959266
ABSTRACT
In the field of ultra-high field MR imaging, the challenges associated with higher frequencies and shorter wavelengths necessitate rigorous attention to multichannel array design. While the need for such arrays remains, and efforts to increase channel counts continue, a persistent impediment-inter-element coupling-constantly hinders development. This coupling degrades current and field distribution, introduces noise correlation between channels, and alters the frequency of array elements, affecting image quality and overall performance. The goal of optimizing ultra-high field MRI goes beyond resolving inter-element coupling and includes significant safety considerations related to the design changes required to achieve high-impedance coils. Although these coils provide excellent isolation, the higher impedance needs special design changes. However, such changes pose a significant safety risk in the form of strong electric fields across low-capacitance lumped components. This process may raise Specific Absorption Rate (SAR) values in the imaging subject, increasing power deposition and, as a result, the risk of tissue heating-related injury. To balance the requirement of inter-element decoupling with the critical need for safety, we suggest a new solution. Our method uses high-dielectric materials to efficiently reduce electric fields and SAR values in the imaging sample. This intervention tries to maintain B1 efficiency and inter-element decoupling within the existing array design, which includes high-impedance coils. Our method aims to promote the full potential of ultra-high field MRI by alleviating this critical safety concern with minimal changes to the existing array setup.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Impedancia Eléctrica Límite: Humans Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos