Your browser doesn't support javascript.
loading
Comparative Analysis of Protein Quantification by the SomaScan Assay versus Orthogonal Methods in Urine from People with Diabetic Kidney Disease.
Lopez, Lauren N; Durbin-Johnson, Blythe; Vargas, Chenoa R; Ruzinski, John; Goodling, Anne; Mehrotra, Rajnish; Vaisar, Tomas; Rocke, David M; Afkarian, Maryam.
Afiliación
  • Lopez LN; Division of Nephrology, Department of Medicine, University of California, Davis, California 95616, United States.
  • Durbin-Johnson B; Division of Biostatistics, Department of Public Health Sciences, School of Medicine, University of California, Davis, California 95616, United States.
  • Vargas CR; Division of Nephrology, Department of Medicine, University of California, Davis, California 95616, United States.
  • Ruzinski J; Kidney Research Institute, Division of Nephrology, Department of Medicine, University of Washington, Seattle, Washington 98195, United States.
  • Goodling A; Kidney Research Institute, Division of Nephrology, Department of Medicine, University of Washington, Seattle, Washington 98195, United States.
  • Mehrotra R; Kidney Research Institute, Division of Nephrology, Department of Medicine, University of Washington, Seattle, Washington 98195, United States.
  • Vaisar T; Diabetes Institute, Division of Metabolism, Endocrinology and Nutrition, Department of Medicine, University of Washington, Seattle,Washington98195,United States.
  • Rocke DM; Division of Biostatistics, Department of Public Health Sciences, School of Medicine, University of California, Davis, California 95616, United States.
  • Afkarian M; Division of Nephrology, Department of Medicine, University of California, Davis, California 95616, United States.
J Proteome Res ; 23(7): 2598-2607, 2024 Jul 05.
Article en En | MEDLINE | ID: mdl-38965919
ABSTRACT
To our knowledge, calibration curves or other validations for thousands of SomaScan aptamers are not publicly available. Moreover, the abundance of urine proteins obtained from these assays is not routinely validated with orthogonal methods (OMs). We report an in-depth comparison of SomaScan readout for 23 proteins in urine samples from patients with diabetic kidney disease (n = 118) vs OMs, including liquid chromatography-targeted mass spectrometry (LC-MS), ELISA, and nephelometry. Pearson correlation between urine abundance of the 23 proteins from SomaScan 3.2 vs OMs ranged from -0.58 to 0.86, with a median (interquartile ratio, [IQR]) of 0.49 (0.18, 0.53). In multivariable linear regression, the SomaScan readout for 6 of the 23 examined proteins (26%) was most strongly associated with the OM-derived abundance of the same (target) protein. For 3 of 23 (13%), the SomaScan and OM-derived abundance of each protein were significantly associated, but the SomaScan readout was more strongly associated with OM-derived abundance of one or more "off-target" proteins. For the remaining 14 proteins (61%), the SomaScan readouts were not significantly associated with the OM-derived abundance of the targeted proteins. In 6 of the latest group, the SomaScan readout was not associated with urine abundance of any of the 23 quantified proteins. To sum, over half of the SomaScan results could not be confirmed by independent orthogonal methods.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Nefropatías Diabéticas Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Proteome Res Asunto de la revista: BIOQUIMICA Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Nefropatías Diabéticas Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Proteome Res Asunto de la revista: BIOQUIMICA Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos