Your browser doesn't support javascript.
loading
Area under the curve and amplitude of the compound motor action potential are clinically interchangeable quantitative measures of neuromuscular block: a method comparison study.
Epstein, Richard H; Nemes, Réka; Renew, Johnathan R; Brull, Sorin J.
Afiliación
  • Epstein RH; Department of Anesthesiology, Perioperative Medicine & Pain Management, University of Miami, Miller School of Medicine, Miami, FL, USA.
  • Nemes R; Department of Anesthesiology and Intensive Care, University of Debrecen, Debrecen, Hungary.
  • Renew JR; Department of Anesthesiology and Perioperative Medicine, Mayo Clinic College of Medicine and Science, Jacksonville, FL, USA.
  • Brull SJ; Department of Anesthesiology and Perioperative Medicine, Mayo Clinic College of Medicine and Science, Jacksonville, FL, USA.
BJA Open ; 11: 100293, 2024 Sep.
Article en En | MEDLINE | ID: mdl-38974718
ABSTRACT

Background:

Current guidelines recommend quantitative neuromuscular block monitoring during neuromuscular blocking agent administration. Monitors using surface electromyography (EMG) determine compound motor action potential (cMAP) amplitude or area under the curve (AUC). Rigorous evaluation of the interchangeability of these methods is lacking but necessary for clinical and research assurance that EMG interpretations of the depth of neuromuscular block are not affected by the methodology.

Methods:

Digitised EMG waveforms were studied from 48 patients given rocuronium during two published studies. The EMG amplitudes and AUCs were calculated pairwise from all cMAPs classified as valid by visual inspection. Ratios of the first twitch (T1) to the control T1 before administration of rocuronium (T1c) and train-of-four ratios (TOFRs) were compared using repeated measures Bland-Altman analysis.

Results:

Among the 2419 paired T1/T1c differences where the average T1/T1c was ≤0.2, eight (0.33%) were outside prespecified clinical limits of agreement (-0.148 to 0.164). Among the 1781 paired TOFR differences where the average TOFR was ≥0.8, 70 (3.93%) were outside the prespecified clinical limits of agreement ((-0.109 to 0.134). Among all 7286 T1/T1c paired differences, the mean bias was 0.32 (95% confidence interval 0.202-0.043), and among all 5559 paired TOFR differences, the mean bias was 0.011 (95% confidence interval 0.0050-0.017). Among paired T1/T1c and TOFR differences, Lin's concordance correlation coefficients were 0.98 and 0.995, respectively. Repeatability coefficients for T1/T1c and TOFR were <0.08, with no differences between methods.

Conclusions:

Quantitative assessment neuromuscular block depth is clinically interchangeable when calculated using cMAP amplitude or the AUC.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: BJA Open Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: BJA Open Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido