Your browser doesn't support javascript.
loading
A new colorimetric lactate biosensor based on CUPRAC reagent using binary enzyme (lactate-pyruvate oxidases)-immobilized silanized magnetite nanoparticles.
Ayaz, Selen; Ersan, Teslime; Dilgin, Yusuf; Apak, Resat.
Afiliación
  • Ayaz S; Department of Chemistry, Faculty of Science, Çanakkale Onsekiz Mart University, Canakkale, 17020, Turkey.
  • Ersan T; Department of Chemistry, Faculty of Science, Çanakkale Onsekiz Mart University, Canakkale, 17020, Turkey.
  • Dilgin Y; Department of Chemistry, Faculty of Science, Çanakkale Onsekiz Mart University, Canakkale, 17020, Turkey. ydilgin@comu.edu.tr.
  • Apak R; Department of Chemistry, Faculty of Engineering, Istanbul University-Cerrahpasa, Avcilar, 34320, Istanbul, Turkey. rapak@istanbul.edu.tr.
Mikrochim Acta ; 191(8): 455, 2024 07 09.
Article en En | MEDLINE | ID: mdl-38980437
ABSTRACT
A novel optical lactate biosensor is presented that utilizes a colorimetric interaction between H2O2 liberated by a binary enzymatic reaction and bis(neocuproine)copper(II) complex ([Cu(Nc)2]2+) known as CUPRAC (cupric reducing antioxidant capacity) reagent. In the first step, lactate oxidase (LOx) and pyruvate oxidase (POx) were separately immobilized on silanized magnetite nanoparticles (SiO2@Fe3O4 NPs), and thus, 2 mol of H2O2 was released per 1 mol of the substrate due to a sequential enzymatic reaction of the mixture of LOx-SiO2@Fe3O4 and POx-SiO2@Fe3O4 NPs with lactate and pyruvate, respectively. In the second step, the absorbance at 450 nm of the yellow-orange [Cu(Nc)2]+ complex formed through the color reaction of enzymatically produced H2O2 with [Cu(Nc)2]2+ was recorded. The results indicate that the developed colorimetric binary enzymatic biosensor exhibits a broad linear range of response between 0.5 and 50.0 µM for lactate under optimal conditions with a detection limit of 0.17 µM. The fabricated biosensor did not respond to other saccharides, while the positive interferences of certain reducing compounds such as dopamine, ascorbic acid, and uric acid were minimized through their oxidative removal with a pre-oxidant (NaBiO3) before enzymatic and colorimetric reactions. The fabricated optical biosensor was applied to various samples such as artificial blood, artificial/real sweat, and cow milk. The high recovery values (close to 100%) achieved for lactate-spiked samples indicate an acceptable accuracy of this colorimetric biosensor in the determination of lactate in real samples. Due to the increase in H2O2 production with the bienzymatic lactate sensor, the proposed method displays double-fold sensitivity relative to monoenzymatic biosensors and involves a neat color reaction with cupric-neocuproine having a clear stoichiometry as opposed to the rather indefinite stoichiometry of analogous redox dye methods.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Piruvato Oxidasa / Técnicas Biosensibles / Colorimetría / Ácido Láctico / Cobre / Enzimas Inmovilizadas / Nanopartículas de Magnetita / Peróxido de Hidrógeno / Oxigenasas de Función Mixta Límite: Animals Idioma: En Revista: Mikrochim Acta Año: 2024 Tipo del documento: Article País de afiliación: Turquía

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Piruvato Oxidasa / Técnicas Biosensibles / Colorimetría / Ácido Láctico / Cobre / Enzimas Inmovilizadas / Nanopartículas de Magnetita / Peróxido de Hidrógeno / Oxigenasas de Función Mixta Límite: Animals Idioma: En Revista: Mikrochim Acta Año: 2024 Tipo del documento: Article País de afiliación: Turquía