Your browser doesn't support javascript.
loading
Successful revascularization of coronary occlusion due to lotus root-like plaques by IVUS-based real-time three-dimensional wiring using the tip detection method in a patient with cardiac arrest.
Okamoto, Akihiro; Yamaguchi, Tomohiro; Yamazaki, Takanori; Fukuda, Daiju.
Afiliación
  • Okamoto A; Department of Cardiovascular Medicine, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan.
  • Yamaguchi T; Department of Cardiovascular Medicine, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan.
  • Yamazaki T; Department of Cardiovascular Medicine, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan.
  • Fukuda D; Department of Cardiovascular Medicine, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan.
Catheter Cardiovasc Interv ; 104(2): 252-255, 2024 Aug.
Article en En | MEDLINE | ID: mdl-38984675
ABSTRACT
A 32-year-old man, who was treated for T-cell lymphoma, presented in cardiac arrest. He had been treated for heart failure with reduced ejection fraction. Veno-arterial extracorporeal membrane oxygenation was initiated immediately. We diagnosed him as non-ST elevated myocardial infarction. Coronary angiography demonstrated the occlusion of the trifurcation in the proximal left anterior descending artery (LAD). We failed to advance the first guidewire into the distal LAD by angio-based conventional wiring. Intravascular ultrasonography (IVUS) of the proximal diagonal branch revealed two diaphragms separating the distal lumen without connection, which looks like lotus root-like appearance. We quickly penetrated the plaque using IVUS-based real-time 3D wiring using the tip detection method. The contrast injection via the microcatheter showed the distal diagonal branch (D2). After the balloon dilation in D2, IVUS image revealed a torn plaque between D2 and the distal LAD. Subsequently we advanced the guidewire to the distal LAD using IVUS-based real-time 3D wiring using the tip detection method through the tear of the plaque. Finally, we successfully performed the revascularization of LAD in a preferable procedure time. The patient recovered well and was discharged 39 days after cardiac arrest. This case highlights the efficacy of IVUS-based real-time 3D wiring using the tip detection method even in the emergent and challenging situation.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Angiografía Coronaria / Ultrasonografía Intervencional / Oclusión Coronaria / Placa Aterosclerótica / Paro Cardíaco Límite: Adult / Humans / Male Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Angiografía Coronaria / Ultrasonografía Intervencional / Oclusión Coronaria / Placa Aterosclerótica / Paro Cardíaco Límite: Adult / Humans / Male Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Estados Unidos