[Application of external fixator combined with Kirschner wire fixation for oblique and comminuted distal humeral metaphyseal-diaphyseal junction fractures in children].
Shen, Xiangyang; Jia, Guoqiang; Zhang, Sicheng.
Afiliación
  • Shen X; Department of Orthopedics, Anhui Medical University Children's Medical Center/Anhui Provincial Children's Hospital, Hefei Anhui, 230051, P. R. China.
  • Jia G; The Fifth Clinical College of Anhui Medical University, Hefei Anhui, 230000, P. R. China.
  • Zhang S; Department of Orthopedics, Anhui Medical University Children's Medical Center/Anhui Provincial Children's Hospital, Hefei Anhui, 230051, P. R. China.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(7): 862-866, 2024 Jul 15.
Article en Zh | MEDLINE | ID: mdl-39013825
ABSTRACT

Objective:

To analyze the effectiveness of external fixator combined with Kirschner wire (EF-KW) fixation in the treatment of oblique and comminuted distal humeral metaphyseal-diaphyseal junction (DHMDJ) fractures in children.

Methods:

A clinical data of 22 children with DHMDJ fractures who met the selection criteria between April 2021 and December 2023 was retrospectively analyzed. All patients were treated with EF-KW fixation. There were 14 boys and 8 girls with an average age of 6.8 years (range, 1.5-12.0 years). The time from injury to operation was 14-38 hours (mean, 24.2 hours). There were 18 cases of comminuted fractures and 4 cases of oblique fractures; and 1 case of median nerve injury and 1 case of radial nerve injury before operation. The occurrence of postoperative complications was recorded. At last follow-up, the function of the affected elbow joint was evaluated according to the Mayo elbow joint function score, and the Baumann's angle (BA) and humero-capitellar angle (HCA) of the affected and healthy sides were recorded and compared.

Results:

All fractures were successfully treated with closed reduction and no complications such as nerve injury occurred. Superficial infection occurred in 4 cases after operation and healed after symptomatic treatment. The incisions of other patients healed by first intention. All patients were followed up 9-24 months (mean, 13.8 months). At last follow-up, according to the Mayo elbow joint function score, the elbow joint function was rated as excellent in 15 cases, good in 6 cases, and fair in 1 case, with an excellent and good rate of 95.5%. The neurologic injury before operation recovered gradually. X-ray films reexamination showed that all fractures healed, and the healing time of fractures ranged from 29 to 61 days, with an average of 35.6 days. At last follow-up, there was no significant difference in BA and HCA between the healthy side and the affected side ( P>0.05). During follow-up, 1 case developed mild cubitus varus, while the other patients had no serious complications.

Conclusion:

EF-KW fixation for oblique and comminuted DHMDJ fractures in children has the advantages of less trauma, simple operation, easy reduction, good stability after reduction, low incidence of serious complications, and good elbow functional recovery.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hilos Ortopédicos / Fijadores Externos / Fracturas Conminutas / Fracturas del Húmero Límite: Child / Child, preschool / Female / Humans / Infant / Male Idioma: Zh Revista: Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi Año: 2024 Tipo del documento: Article Pais de publicación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hilos Ortopédicos / Fijadores Externos / Fracturas Conminutas / Fracturas del Húmero Límite: Child / Child, preschool / Female / Humans / Infant / Male Idioma: Zh Revista: Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi Año: 2024 Tipo del documento: Article Pais de publicación: China