Your browser doesn't support javascript.
loading
Screen-Printed Electrodes-A Promising Tool for Antineoplastic Drug Detection (Cisplatin and Bleomycin) in Biological Samples.
Mirica Ion, Andreea-Cristina; Stan, Dana; Zaharia, Dragos-Cosmin; Iovu, Horia; Mocanu, Sorin; Avram, Marioara; Bocancia-Mateescu, Lorena-Andreea.
Afiliación
  • Mirica Ion AC; DDS Diagnostic, 032032 Bucharest, Romania.
  • Stan D; Advanced Polymer Materials Group, University Politehnica of Bucharest, 1-7 Gh. Polizu Street, 011061 Bucharest, Romania.
  • Zaharia DC; DDS Diagnostic, 032032 Bucharest, Romania.
  • Iovu H; DDS Diagnostic, 032032 Bucharest, Romania.
  • Mocanu S; Department of Pneumology I, Carol Davila University of Medicine and Pharmacy, 020021 Bucharest, Romania.
  • Avram M; Advanced Polymer Materials Group, University Politehnica of Bucharest, 1-7 Gh. Polizu Street, 011061 Bucharest, Romania.
  • Bocancia-Mateescu LA; DDS Diagnostic, 032032 Bucharest, Romania.
Int J Mol Sci ; 25(15)2024 Jul 23.
Article en En | MEDLINE | ID: mdl-39125599
ABSTRACT
Cancer remains one of the leading causes for death worldwide. Palliative chemotherapy is vital for certain cancer patients, highlighting the critical need for treatment monitoring tools to prevent drug accumulation and mitigate the risk of high toxicity. Therefore, our aim was to evaluate the potential of screen-printed electrodes for the development of sensitive and accurate biosensors for the detection/quantification of antineoplastic drugs. To this purpose, we developed a cisplatin sensor. By functionalizing the gold electrode with human serum albumin and by collecting the electrochemical signal obtained in a H2O2 solution, through voltammetry measurements, we were able to correlate the current measured at 430 mV with the concentration of cisplatin present in human serum samples, with a correlation coefficient of R2 = 0.99. Also, a bleomycin biosensor was developed and proven functional, but further optimization steps were employed in order to improve the accuracy. The developed biosensors have a detection range of 0.0006-43.2 mg/mL for cisplatin and 0.23-7.56 µg/mL for bleomycin in the serum samples. Our preliminary results show that these biosensors can facilitate the real-time monitoring of cisplatin and bleomycin serum levels, allowing healthcare professionals to tailor treatment strategies based on individual patient responses.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Bleomicina / Técnicas Biosensibles / Cisplatino / Electrodos / Antineoplásicos Límite: Humans Idioma: En Revista: Int J Mol Sci Año: 2024 Tipo del documento: Article País de afiliación: Rumanía Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Bleomicina / Técnicas Biosensibles / Cisplatino / Electrodos / Antineoplásicos Límite: Humans Idioma: En Revista: Int J Mol Sci Año: 2024 Tipo del documento: Article País de afiliación: Rumanía Pais de publicación: Suiza