Your browser doesn't support javascript.
loading
Highly efficient electrocatalytic oxidation of levodopa as a Parkinson therapeutic drug based on modified screen-printed electrode.
Wang, Tan; Jafar, Nadhir N A; Al-Rihaymee, Afrah Majeed Ahmed; Alhameedi, Dheyaa Yahaia; Rasen, Fadhil A; Hashim, Furqan S; Hussein, Talib Kh; Ramadan, Montather F; Alasedi, Kasim Kadhim; Suliman, Muath; Alawadi, Ahmed Hussien.
Afiliación
  • Wang T; Three Gorges University, College of Basie Medical Scienees, 443002, China.
  • Jafar NNA; Al-Zahraa Center for Medical and Pharmaceutical Research Sciences (ZCMRS), Al-Zahraa University for Women, Karbala, 56001, Iraq.
  • Al-Rihaymee AMA; Anesthesia Techniques Department, College of Health and Medical Techniques, Al-Mustaqbal University, 51001, Babylon, Iraq.
  • Alhameedi DY; Department of Anesthesia, College of health & medical Technology, Sawa University, Almuthana, Iraq.
  • Rasen FA; Department of Medical Engineering, Al-Esraa University College, Baghdad, Iraq.
  • Hashim FS; Department of Medical Laboratories Technology, AL-Nisour University College, Baghdad, Iraq.
  • Hussein TK; Al-Hadi University College, Baghdad, 10011, Iraq.
  • Ramadan MF; College of Dentistry, Al-Ayen University, Thi-Qar, Iraq.
  • Alasedi KK; Department of Medical Laboratory Techniques, Altoosi University College, Najaf, Iraq.
  • Suliman M; Department of Clinical Laboratory Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia.
  • Alawadi AH; College of technical engineering, the Islamic University, Najaf, Iraq.
Heliyon ; 10(14): e34689, 2024 Jul 30.
Article en En | MEDLINE | ID: mdl-39149019
ABSTRACT
The current study presents the creation of a straightforward and sensitive sensor based on ZnO/Co3O4 nanocomposite modified screen-printed electrode (ZnO/Co3O4NC/SPE) for levodopa determination. At ZnO/Co3O4NC/SPE, an oxidative peak for levodopa solution in pH 6.0 phosphate buffer solution (PBS) were seen that were both more resolved and more enhanced. Levodopa was measured using differential pulse voltammetry (DPV), which showed an excellent linear range (0.001-800.0 µM) and detection limit (0.81 nM). The presence of interference did not affect the electrochemical response of levodopa at ZnO/Co3O4NC/SPE, demonstrating high selectivity. Levodopa in a real samples have been successfully detected using the manufactured sensor.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Heliyon Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Heliyon Año: 2024 Tipo del documento: Article País de afiliación: China