Your browser doesn't support javascript.
loading
Evaluation of Freezanz automated misting system against mosquitoes.
Farooq, Muhammad; Talbalaghi, Asghar; Xue, Rui-De.
Afiliación
  • Farooq M; Anastasia Mosquito Control District, 120 EOC Drive, St. Augustine, F 32092, USA. Electronic address: mfarooq@amcdfl.org.
  • Talbalaghi A; Italian Mosquito Control Association (IMCA), San Lazzaro di Savena (BO), Italy.
  • Xue RD; Anastasia Mosquito Control District, 120 EOC Drive, St. Augustine, F 32092, USA.
Acta Trop ; : 107369, 2024 Aug 29.
Article en En | MEDLINE | ID: mdl-39216811
ABSTRACT
Automated misting systems are a convenient way for homeowners or small businesses to control adult mosquitoes. One such system was presented to the Anastasia Mosquito Control District (AMCD) for evaluation to control caged Aedes aegypti. The system consisted of 3 spray tanks, 2 pumps, water level sensors, and flow meters, and was controlled through an Android tablet loaded with dedicated control software. The evaluation of the system included calibration tests, droplet characterization, spray dispersion in the open field, and effectiveness testing using bio-assay cages for mortality assessment. For these tests, a loop of 14 nozzles 4 m apart was connected and held at 1 m height utilizing a total of 120 m tube. All nozzles were arranged in a 16 × 12 m rectangle laid in the East-West direction. Water was sprayed for calibration and droplet size measurements at pressures of 13.0, 15.5, and 18 bar; water and 10% red dye solution for spray dispersion at 18 bar pressure, and 0.17% solution of equalizer 20-20 was sprayed at 18 bar pressure for mortality tests. All 3 replicated tests were conducted in the morning between 900 and 1130 am. During this time, temperature ranged from 21-26°C, relative humidity from 54-95 %, and wind speed from 0 - 2 km/hr. The combined flow rate from all 14 nozzles was significantly affected by pressure and was in agreement with the machine-calculated flow rate. There was a similar flow rate from all nozzles, indicated by a standard error of 0.82 mL/min. The droplet characteristics represented by DV0.1, DV0.5, and DV0.9 were not affected by nozzles but decreased with an increase in pressure as expected. The percentage of coverage on the cards, an indicator of spray dispersion, ranged from 20 -100 %, and it was found to increase in the direction of the wind. Mosquito mortality showed a similar trend of increasing in the wind direction and ranged from 30 to 100%. There was no effect of the location of cages on mosquito mortality. These results indicate that the effectiveness of this spray depends upon wind direction. The results, however, may be different when there is no wind, which may be the case during the times these applications are made.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Acta Trop Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Acta Trop Año: 2024 Tipo del documento: Article