[Study on direct ventricular assist loading mode based on a finite element method].
Li, Chen; Jiang, Xianjie; Zhang, Sheng; Wang, Tianbo; Liu, Xiaohan; Zhang, Yue; Huang, Gang; Zhang, Xiaogang; Xu, Junbo; Jin, Zhongmin.
Afiliación
  • Li C; School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, P. R. China.
  • Jiang X; School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, P. R. China.
  • Zhang S; School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, P. R. China.
  • Wang T; The third people's hospital of Chengdu (Affiliated hospital of Southwest Jiaotong University), Chengdu 610031, P. R. China.
  • Liu X; The third people's hospital of Chengdu (Affiliated hospital of Southwest Jiaotong University), Chengdu 610031, P. R. China.
  • Zhang Y; The third people's hospital of Chengdu (Affiliated hospital of Southwest Jiaotong University), Chengdu 610031, P. R. China.
  • Huang G; The third people's hospital of Chengdu (Affiliated hospital of Southwest Jiaotong University), Chengdu 610031, P. R. China.
  • Zhang X; School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, P. R. China.
  • Xu J; The third people's hospital of Chengdu (Affiliated hospital of Southwest Jiaotong University), Chengdu 610031, P. R. China.
  • Jin Z; School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, P. R. China.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(4): 782-789, 2024 Aug 25.
Article en Zh | MEDLINE | ID: mdl-39218605
ABSTRACT
To investigate the biomechanical effects of direct ventricular assistance and explore the optimal loading mode, this study established a left ventricular model of heart failure patients based on the finite element method. It proposed a loading mode that maintains peak pressure compression, and compared it with the traditional sinusoidal loading mode from both hemodynamic and biomechanical perspectives. The results showed that both modes significantly improved hemodynamic parameters, with ejection fraction increased from a baseline of 29.33% to 37.32% and 37.77%, respectively, while peak pressure, stroke volume, and stroke work parameters also increased. Additionally, both modes showed improvements in stress concentration and excessive fiber strain. Moreover, considering the phase error of the assist device's working cycle, the proposed assist mode in this study was less affected. Therefore, this research may provide theoretical support for the design and optimization of direct ventricular assist devices.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Corazón Auxiliar / Análisis de Elementos Finitos / Insuficiencia Cardíaca Límite: Humans Idioma: Zh Revista: Sheng Wu Yi Xue Gong Cheng Xue Za Zhi Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article Pais de publicación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Corazón Auxiliar / Análisis de Elementos Finitos / Insuficiencia Cardíaca Límite: Humans Idioma: Zh Revista: Sheng Wu Yi Xue Gong Cheng Xue Za Zhi Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article Pais de publicación: China