[Determination of 8 N-nitrosamines in the workplace air by GC-MS/MS method].
Meng, X J; Liu, X D; Zhang, X M; Hu, Y; Guo, Q F.
Afiliación
  • Meng XJ; Central Laboratory, the Beijing Prevention and Treatment Hospital of Occupational Disease for Chemical Industry, Beijing 100093, China.
  • Liu XD; Central Laboratory, the Beijing Prevention and Treatment Hospital of Occupational Disease for Chemical Industry, Beijing 100093, China.
  • Zhang XM; Central Laboratory, the Beijing Prevention and Treatment Hospital of Occupational Disease for Chemical Industry, Beijing 100093, China.
  • Hu Y; Central Laboratory, the Beijing Prevention and Treatment Hospital of Occupational Disease for Chemical Industry, Beijing 100093, China.
  • Guo QF; Central Laboratory, the Beijing Prevention and Treatment Hospital of Occupational Disease for Chemical Industry, Beijing 100093, China.
Article en Zh | MEDLINE | ID: mdl-39223051
ABSTRACT

Objective:

To establish a method for the determination of eight N-nitrosamines (N-nitrosodimethylamine, N-nitrosodimethylamine, N-nitrosomethylmethylamine, N-nitrosodibutylamine, N-nitrosopropylamine, N-nitrosomorpholine, N-nitrosodianiline and N-nitrosopiperidine) in the air of workplace by gas chromatography-tandem mass spectrometry (GC-MS/MS) .

Methods:

From January to August 2023, eight N-nitrosamines in the air of workplace were collected by ThermoSorb/N column, eluted with 4 ml methanol-dichloromethane (1∶1 volume ratio), separated by VF-624 ms capillary column, detected by multiple reaction monitoring mode and quantified by external standard method. The detection limit and precision of the method were also analyzed.

Results:

The linear range of the method for the determination of eight N-nitrosamines was 1.0-20.0 µg/L, the correlation coefficient was 0.9993-0.9999, the detection limit was 0.051-0.132 µg/L, and the minimum quantitative concentration was 0.030-0.078 µg/m(3) (calculated by collecting 22.5 L of air sample and eluting with 4.0 ml stripping liquid). The within-run precisions were 2.05%-6.89% and the between-run precisions were 2.41%-8.26%. The desorption rates were 67.20%-102.60%. The sample can be kept at least 7 days at 4 ℃.

Conclusion:

GC-MS/MS method for the determination of eight N-nitrosamines in workplace air has high sensitivity and good precision, and can accurately determine the content of eight N-nitrosamines in workplace air.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Lugar de Trabajo / Contaminantes Ocupacionales del Aire / Espectrometría de Masas en Tándem / Cromatografía de Gases y Espectrometría de Masas / Nitrosaminas Idioma: Zh Revista: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi Asunto de la revista: MEDICINA OCUPACIONAL Año: 2024 Tipo del documento: Article País de afiliación: China Pais de publicación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Lugar de Trabajo / Contaminantes Ocupacionales del Aire / Espectrometría de Masas en Tándem / Cromatografía de Gases y Espectrometría de Masas / Nitrosaminas Idioma: Zh Revista: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi Asunto de la revista: MEDICINA OCUPACIONAL Año: 2024 Tipo del documento: Article País de afiliación: China Pais de publicación: China