Dual-chamber vs. single-chamber pacemaker in patients in sinus rhythm with an atrioventricular block: a nationwide cohort study.
Bodin, Alexandre; Texier, Ivann; Bisson, Arnaud; Pierre, Bertrand; Herbert, Julien; Jacobs, Mathieu; Nasarre, Mathieu; Bernard, Anne; Fauchier, Laurent.
Afiliación
  • Bodin A; Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France.
  • Texier I; Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France.
  • Bisson A; Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France.
  • Pierre B; Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France.
  • Herbert J; Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France.
  • Jacobs M; Service d'Information Médicale, D'épidémiologie et d'Économie de la Santé, Centre Hospitalier Universitaire et EA7505, Faculté de Médecine, Université François Rabelais, 37000 Tours, France.
  • Nasarre M; Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France.
  • Bernard A; Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France.
  • Fauchier L; Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France.
Europace ; 26(9)2024 Aug 30.
Article en En | MEDLINE | ID: mdl-39271128
ABSTRACT

AIMS:

In complete atrioventricular block (AVB) with underlying sinus rhythm, it is recommended to implant a dual-chamber pacemaker rather than a single-chamber pacemaker. However, no large-scale study has been able to demonstrate the superiority of this choice on hard clinical criteria such as morbimortality. METHODS AND

RESULTS:

This retrospective observational study included all patients who received a primary pacemaker implantation in the indication of complete AVB with underlying sinus rhythm in France, based on the national administrative database between January 2013 and December 2022. After propensity score matching, we obtained two groups containing 19 219 patients each. The incidence of all-cause mortality was 9.22%/year for the dual-chamber pacemaker group, compared with 11.48%/year for the single-chamber pacemaker group (hazard ratio (HR) 0.807, P < 0.0001]. Similarly, there was a lower incidence of cardiovascular mortality (HR 0.766, P < 0.0001), heart failure (HR 0.908, P < 0.0001), atrial fibrillation (HR 0.778, P < 0.0001), and ischaemic stroke (HR 0.873, P = 0.008) in the dual-chamber pacemaker group than in the single-chamber pacemaker group. Regarding re-interventions and complications, there were fewer upgrades (addition of atrial lead or left ventricular lead) in the dual-chamber group (HR 0.210, P < 0.0001), but more haematomas (HR 1.179, P = 0.006) and lead repositioning (HR 1.123, P = 0.04).

CONCLUSION:

In the indication of complete AVB with underlying sinus rhythm, our results are consistent with current recommendations to prefer implantation of a dual-chamber pacemaker rather than a single-chamber pacemaker for these patients. Implantation of a dual-chamber pacemaker is associated with a lower risk of mortality, heart failure, atrial fibrillation, and stroke during follow-up.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Marcapaso Artificial / Bloqueo Atrioventricular Límite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: Europace Asunto de la revista: CARDIOLOGIA / FISIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Marcapaso Artificial / Bloqueo Atrioventricular Límite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: Europace Asunto de la revista: CARDIOLOGIA / FISIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Reino Unido