Your browser doesn't support javascript.
loading
Usefulness of Hem-o-lok® clips to ligate the gastroduodenal artery in pancreatoduodenectomy.
Kubo, Norio; Suzuki, Shigemasa; Seki, Takahiro; Fukushima, Ryosuke; Furuke, Shunsaku; Yagi, Naoki; Ooki, Takashi; Aihara, Ryusuke; Araki, Kenichiro; Hosouchi, Yasuo; Shirabe, Ken.
Afiliación
  • Kubo N; Department of Surgery, Gunma Prefecture Saiseikai Maebashi Hospital, Maebashi, Japan. Electronic address: nkubo@gunma-u.ac.jp.
  • Suzuki S; Department of Surgery, Gunma Prefecture Saiseikai Maebashi Hospital, Maebashi, Japan.
  • Seki T; Department of Surgery, Gunma Prefecture Saiseikai Maebashi Hospital, Maebashi, Japan.
  • Fukushima R; Department of Surgery, Gunma Prefecture Saiseikai Maebashi Hospital, Maebashi, Japan.
  • Furuke S; Department of Surgery, Gunma Prefecture Saiseikai Maebashi Hospital, Maebashi, Japan.
  • Yagi N; Department of Surgery, Gunma Prefecture Saiseikai Maebashi Hospital, Maebashi, Japan.
  • Ooki T; Department of Surgery, Gunma Prefecture Saiseikai Maebashi Hospital, Maebashi, Japan.
  • Aihara R; Department of Surgery, Gunma Prefecture Saiseikai Maebashi Hospital, Maebashi, Japan.
  • Araki K; Division of Hepatobiliary and Pancreatic Surgery, Department of General Surgical Science, Graduate School of Medicine, Gunma University, Maebashi, Japan.
  • Hosouchi Y; Department of Surgery, Gunma Prefecture Saiseikai Maebashi Hospital, Maebashi, Japan.
  • Shirabe K; Division of Hepatobiliary and Pancreatic Surgery, Department of General Surgical Science, Graduate School of Medicine, Gunma University, Maebashi, Japan.
HPB (Oxford) ; 2024 Sep 03.
Article en En | MEDLINE | ID: mdl-39289132
ABSTRACT
BACKGROUND/

PURPOSE:

Post-pancreatectomy hemorrhage (PPH) is a fatal complication of pancreatoduodenectomy. When complicated by a pancreatic fistula, pancreatic juice contacting the artery may form a pseudoaneurysm and cause arterial bleeding. We used Hem-o-lok® clips to prevent damage to the outer wall of the gastroduodenal artery (GDA). This study evaluated the usefulness of using Hem-o-lok® clips to ligate the GDA stump to prevent PPH.

METHODS:

Overall, 468 patients who underwent PD at our hospital were included. Before July 2020, we ligated the GDA stump using the knot-tying method, which involves double ligation. After July 2020, the GDA stump was double clipped using a 10-mm Hem-o-lok® clip to the residual side without tension on the GDA. Propensity score matching was used to compare cases of pancreatic fistulas that underwent clipping vs. knot-tying.

RESULTS:

Propensity score matching resulted in 37 patients in each group. PPH occurred in 12 (16.4%) and 4 (6.9%) patients in the knot-tying and clipping groups, respectively. PPH from the GDA stump occurred in eight (11.0%) and one (1.7%) patient in the knot tying and clipping groups, respectively (P = 0.044).

CONCLUSIONS:

Hem-o-lok® clips are safe to apply on the GDA stump during pancreatoduodenectomy to prevent PPH.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: HPB (Oxford) Asunto de la revista: GASTROENTEROLOGIA Año: 2024 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: HPB (Oxford) Asunto de la revista: GASTROENTEROLOGIA Año: 2024 Tipo del documento: Article Pais de publicación: Reino Unido