Your browser doesn't support javascript.
loading
Determination of avermectins in plasma at nanogram levels using high-performance liquid chromatography with fluorescence detection.
J Chromatogr ; 190(2): 367-76, 1980 Apr 04.
Article en En | MEDLINE | ID: mdl-7380953
ABSTRACT
An analytical method is described for the determination of the avermectins in plasma based upon high-performance liquid chromatography of fluorescent derivatives of these compounds. The analyte is isolated by adsorption chromatography on Florisil, dehydrated in an acetic anhydride-pyridine mixture, and the fluorophore is further separated by chromatography on silica gel in advance of introduction into a reversed-phase system. This method, which can be applied to samples containing as little as 0.2 ng drug per ml, has an accuracy of 5% mean relative error and a precision of 8% relative standard deviation. A study and discussion of several factors which affect the analytical reaction are included.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ivermectina / Lactonas / Antihelmínticos Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: J Chromatogr Año: 1980 Tipo del documento: Article
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ivermectina / Lactonas / Antihelmínticos Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: J Chromatogr Año: 1980 Tipo del documento: Article