Your browser doesn't support javascript.
loading
Single-donor platelet concentrates produced along with packed red blood cells with the Haemonetics MCS 3p: preliminary results.
Valbonesi, M; Frisoni, R; Florio, G; Ruzzenenti, M R; Capra, C; Merlo, M; Parenti, R.
Afiliación
  • Valbonesi M; Immunohematology Services, S. Martino University Hospital, Genoa, Italy.
J Clin Apher ; 9(3): 195-9, 1994.
Article en En | MEDLINE | ID: mdl-7706202
ABSTRACT
There has been an increasing interest in recent years over the qualitative superiority of single-donor platelets in the management of hemato-oncologic patients. The reasonable desire of both patients and physicians to limit the risks of transfusion along with the need for limiting the costs involved in this kind of therapy have led to application of multicomponent donations both in terms of double platelet concentrates and double products such as red blood cells (RBC) and platelets from the same donor. Single donor platelets and RBC have been collected in a semi-automated mode and only the very recent introduction of the Haemonetics MCS 3p with its SDP/RBC protocol provides a totally closed-system automated protocol for this combined collection. Twenty procedures have been carried out so far at our unit. In a mean of 87 minutes (6-7 passes), a mean of 3.1 x 10(11) platelets were collected along with approximately 220 mL of packed RBC. The leukocyte contamination of the platelet product was in the range of 0.4-1.1 x 10(7) (99% lymphocytes), and the quality of platelets was very satisfactory as measured by the hypotonic shock response, aggregation induced by ADP, collagen and ristocetin, morphology score, and membrane glycoproteins modifications. Equally satisfactory was the quality of the RBC concentrate, suspended in 80 mL of SAG-M, with a total hemoglobin (Hb) content approaching 55 g as compared to the normal Hb content of a standard RBC concentrate that is approximately 62 g.(ABSTRACT TRUNCATED AT 250 WORDS)
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Eliminación de Componentes Sanguíneos / Plaquetoferesis / Eritrocitos Tipo de estudio: Guideline / Qualitative_research Límite: Adult / Female / Humans / Male Idioma: En Revista: J Clin Apher Año: 1994 Tipo del documento: Article País de afiliación: Italia
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Eliminación de Componentes Sanguíneos / Plaquetoferesis / Eritrocitos Tipo de estudio: Guideline / Qualitative_research Límite: Adult / Female / Humans / Male Idioma: En Revista: J Clin Apher Año: 1994 Tipo del documento: Article País de afiliación: Italia