US-guided core biopsy of the breast with a coaxial system.
Radiology
; 194(2): 573-5, 1995 Feb.
Article
en En
| MEDLINE
| ID: mdl-7824740
ABSTRACT
From July 1993 through June 1994, the authors performed 42 ultrasound (US)-guided core biopsies with use of a coaxial technique in which a 14- or 15-gauge core biopsy needle was passed through a 12-gauge introducer needle. This technique proved to be effective in all 42 biopsies. Use of the coaxial technique decreased the procedure time necessary for US-guided core biopsy and may be less traumatic than the standard core biopsy technique.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Biopsia con Aguja
/
Mama
/
Ultrasonografía Intervencional
Límite:
Adult
/
Aged
/
Aged80
/
Humans
/
Middle aged
Idioma:
En
Revista:
Radiology
Año:
1995
Tipo del documento:
Article