[Follow-up study of porcine bioprosthetic valve replacement in 15 children].
Zhonghua Wai Ke Za Zhi
; 32(7): 424-6, 1994 Jul.
Article
en Zh
| MEDLINE
| ID: mdl-7842983
GD-I porcine bioprosthetic valve replacement were performed in 15 cases from Jul. 1978 to Nov. 1982. Pathology: RHD 11, CHD 4, 13 with MVR, 1 AVR, 1 TVR. One patient died during operation (operative mortality 6.7%). 13 cases were followed up for 3-10 years: in the early years the symptoms and cardiac function were greatly improved and the size reduced. However dysfunction of bioprosthetic valve was detected 2-8 years after operation in 12 patients (19.37%/patient year). The main cause of damage and dysfunction of porcine valve is calcification of the leaflet. As compared with the adult group(dysfunction rate 3.6%/patient year) in this institute, more calcification of the porcine valve in children is considered because of: (1) stronger metabolism of calcium in children, (2) less mobility of the leaflet due to lower cardiac output in children, and (3) stronger immunoreaction to porcine valve in children.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Bioprótesis
/
Prótesis Valvulares Cardíacas
/
Cardiopatías Congénitas
Tipo de estudio:
Observational_studies
/
Prognostic_studies
Límite:
Adolescent
/
Child
/
Female
/
Humans
/
Male
Idioma:
Zh
Revista:
Zhonghua Wai Ke Za Zhi
Año:
1994
Tipo del documento:
Article
Pais de publicación:
China