[The application of a periarterial synthetic tube results in the formation of rhythmic structures in the intima]. / Nalozhenie periarterial'noi sinteticheskoi trubki vyzyvaet obrazovanie ritmicheskikh struktur intimy.
Arkh Patol
; 55(3): 46-50, 1993.
Article
en Ru
| MEDLINE
| ID: mdl-7944969
Structure of rabbit carotid artery and aorta after their wrapping with synthetic tube was investigated using light and scanning electron microscopy. Periarterial manipulations lead to the development of myointimal thickening covered with endothelium. Surface of the thickening consisted of rhythmically intermitted elevations and pits situated across the long axis of the vessel. Polymorphism of the covering endothelium was observed. Non-random pattern of the subendothelial smooth muscle cells location (connected with hemodynamic changes) was the main cause of formation of rhythmic structures. Structure of intimal thickening in rabbit arteries is similar to that of human aortic intima at early stages of atherogenesis (before lipid accumulation). This model may be used for studying the mechanisms of atherogenesis as well as for pharmacological investigations.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Aorta Abdominal
/
Arteriosclerosis
/
Arterias Carótidas
/
Túnica Íntima
/
Modelos Animales de Enfermedad
Tipo de estudio:
Prognostic_studies
Límite:
Animals
Idioma:
Ru
Revista:
Arkh Patol
Año:
1993
Tipo del documento:
Article
Pais de publicación:
Rusia