[Hemorrhagic complication following an external shunt for hemodialysis: a clinical case and a proposed technical procedure for its prevention]. / Complicanza emorragica post shunt esterno per emodialisi: caso clinico e proposta di un accorgimento tecnico di prevenzione.
G Chir
; 15(1-2): 37-9, 1994.
Article
en It
| MEDLINE
| ID: mdl-8018474
ABSTRACT
The vascular access for haemodialysis is still a problem not completely solved although surgical experience started more than thirty years ago. Particularly haemorrhagic complications can be dangerous because many patients go home after haemodialysis. The authors report a case in which the disconnection of the conic tip from the shunt cannula for haemodialysis induced an external bleeding, and propose a safety ligature. However, the latter is not necessary for a cannula integrated with the vessel tip.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Complicaciones Posoperatorias
/
Derivación Arteriovenosa Quirúrgica
/
Diálisis Renal
/
Hemorragia
Tipo de estudio:
Etiology_studies
Límite:
Aged
/
Humans
/
Male
Idioma:
It
Revista:
G Chir
Año:
1994
Tipo del documento:
Article