On the sufficiency conditions for the stability of bone remodeling equilibrium.
Cowin, S C; Luo, G M; Sadegh, A M; Harrigan, T P.
Afiliación
  • Cowin SC; Department of Mechanical Engineering, School of Engineering, City College, City University of New York, NY 10031.
J Biomech ; 27(2): 183-6, 1994 Feb.
Article en En | MEDLINE | ID: mdl-8132686
ABSTRACT
In this technical note a sufficiency condition is established for the stability of a strain-energy-based bone remodeling theory in the special case of a beam loaded by an axial force and a bending moment. In a previous report the same condition was shown to be a necessary condition for stability in the same situation. The remodeling scheme is one characterized by a remodeling stimulus equal to the strain energy density divided by the bulk or apparent density raised to an exponent m as well an elastic modulus proportional to bulk or apparent density raised to an exponent n. In order for a remodeling scheme to be stable for an elastic beam loaded by an axial force and a bending moment, it is established that the condition that m must be greater than n is not only necessary, but also sufficient.