Your browser doesn't support javascript.
loading
In vivo observation of subendocardial microvessels of the beating porcine heart using a needle-probe videomicroscope with a CCD camera.
Yada, T; Hiramatsu, O; Kimura, A; Goto, M; Ogasawara, Y; Tsujioka, K; Yamamori, S; Ohno, K; Hosaka, H; Kajiya, F.
Afiliación
  • Yada T; Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School, Kurashiki, Japan.
Circ Res ; 72(5): 939-46, 1993 May.
Article en En | MEDLINE | ID: mdl-8477527
ABSTRACT
We developed a portable needle-probe videomicroscope with a charge-coupled device (CCD) camera to visualize the subendocardial microcirculation. In 12 open-chest anesthetized pigs, the sheathed needle probe with a doughnut-shaped balloon and a microtube for flushing away the intervening blood was introduced into the left ventricle through an incision in the left atrial appendage via the mitral valve. Images of the subendocardial microcirculation of the beating heart magnified by 200 or 400 on a 15-in. monitor were obtained. The phasic diameter change in subendocardial arterioles during cardiac cycle was from 114 +/- 46 microns (mean +/- SD) in end diastole to 84 +/- 26 microns in end systole (p < 0.001, n = 13, ratio of change = 24%) and that in venules from 134 +/- 60 microns to 109 +/- 45 microns (p < 0.001, n = 15, ratio of change = 17%). In contrast, the diameter of subepicardial arterioles was almost unchanged (2% decrease, n = 5, p < 0.01), and the venular diameter increased by 19% (n = 8, p < 0.001) from end diastole to end systole. Partial kinking and/or pinching of vessels was observed in some segments of subendocardial arterioles and venules. The percentage of systolic decrease in the diameter from diastole in the larger (> 100 microns) subendocardial arterioles and venules was greater than smaller (50-100 microns) vessels (both p < 0.05). In conclusion, using a newly developed microscope system, we were able to observe the subendocardial vessels in diastole and systole.(ABSTRACT TRUNCATED AT 250 WORDS)
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Televisión / Circulación Coronaria / Endocardio / Microscopía / Contracción Miocárdica Límite: Animals Idioma: En Revista: Circ Res Año: 1993 Tipo del documento: Article País de afiliación: Japón
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Televisión / Circulación Coronaria / Endocardio / Microscopía / Contracción Miocárdica Límite: Animals Idioma: En Revista: Circ Res Año: 1993 Tipo del documento: Article País de afiliación: Japón