Measurement of acetabular index intraobserver and interobserver variation.
Spatz, D K; Reiger, M; Klaumann, M; Miller, F; Stanton, R P; Lipton, G E.
Afiliación
  • Spatz DK; Alfred I. duPont Institute, Wilmington, Delaware 19899, USA.
J Pediatr Orthop ; 17(2): 174-5, 1997.
Article en En | MEDLINE | ID: mdl-9075091
ABSTRACT
Pelvic radiographs of 25 children aged 6 months to 2 years had the acetabular index measured 3 times by each of five pediatric orthopaedists. Interobserver measurements were found to vary +/-3.0 degrees, whereas the intraobserver variation was +/-3.6 degrees. This error reflects only measurement error and does not consider error introduced with different positioning of the pelvis.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Luxación Congénita de la Cadera / Acetábulo Tipo de estudio: Diagnostic_studies Límite: Child, preschool / Humans / Infant Idioma: En Revista: J Pediatr Orthop Año: 1997 Tipo del documento: Article País de afiliación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Luxación Congénita de la Cadera / Acetábulo Tipo de estudio: Diagnostic_studies Límite: Child, preschool / Humans / Infant Idioma: En Revista: J Pediatr Orthop Año: 1997 Tipo del documento: Article País de afiliación: Estados Unidos