Your browser doesn't support javascript.
loading
Discrepancy between latex and ELISA D-dimer values in sepsis may be caused by human neutrophil elastase.
Bach-Gansmo, E T; Strand, O; Godal, H C; Wisløff, F; Skjønsberg, O H.
Afiliación
  • Bach-Gansmo ET; Department of Pulmonary Medicine, Ullevål Hospital, University of Oslo, Norway. Edvin.Bach-Gansmo@ioks.uio.no
Thromb Res ; 86(2): 141-52, 1997 Apr 15.
Article en En | MEDLINE | ID: mdl-9175235
ABSTRACT
We have recently shown that D-dimers are degraded by human neutrophil elastase (HNE) in vitro, causing rapid decrease in the D-dimer levels measured by a Latex test, but not with an ELISA test employing the same monoclonal antibody against D-dimer. To see if such discrepant D-dimer concentrations occurred in patients with high HNE concentration, we examined 80 plasma samples from 8 patients with sepsis with a Latex and an ELISA test and calculated the ratio between the D-dimer values obtained with the two tests. Twenty healthy pregnant and twenty pre-eclamptic patients, who are known to have raised D-dimer but low HNE concentrations, were chosen as controls. HNE levels were estimated by determining the HNE-alpha 1-proteinase inhibitor complex (HNE-A1PI) concentration. HNE-A1PI concentration was increased in sepsis patients compared with pre-eclamptic patients (p < 0.0005) and healthy pregnant women (p < 0.0005). In sepsis patients, the D-dimer results were skewed towards lower ratios between Latex and ELISA values compared to pre-eclamptic patients (p = 0.008) and healthy pregnant women (p = 0.0001). In plasma samples from patients with the largest discrepancy between Latex and ELISA D-dimer values, Western blotting with immunostaining indicated degradation of D-dimers to D-like fragments similar to those observed following degradation of cross-linked fibrin by HNE in vitro. We conclude that in sepsis patients there is a marked discrepancy between Latex and ELISA D-dimer values that may be caused by HNE. In such patients Latex D-dimer assays may cause severe underestimation of fibrinolysis.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Productos de Degradación de Fibrina-Fibrinógeno / Ensayo de Inmunoadsorción Enzimática / Pruebas de Fijación de Látex / Sepsis / Elastasa de Leucocito Tipo de estudio: Observational_studies Límite: Adult / Female / Humans / Male / Middle aged / Pregnancy Idioma: En Revista: Thromb Res Año: 1997 Tipo del documento: Article País de afiliación: Noruega
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Productos de Degradación de Fibrina-Fibrinógeno / Ensayo de Inmunoadsorción Enzimática / Pruebas de Fijación de Látex / Sepsis / Elastasa de Leucocito Tipo de estudio: Observational_studies Límite: Adult / Female / Humans / Male / Middle aged / Pregnancy Idioma: En Revista: Thromb Res Año: 1997 Tipo del documento: Article País de afiliación: Noruega