Stereotactic and ultrasound core needle breast biopsy performed by surgeons.
Am J Surg
; 174(6): 699-703; discussion 703-4, 1997 Dec.
Article
en En
| MEDLINE
| ID: mdl-9409600
BACKGROUND: The authors evaluated outcomes and treatment costs of stereotactic core needle biopsy (SCNB) and ultrasound core needle biopsy (UCNB), and needle localization biopsy (NLB) in managing patients with mammographic abnormalities presenting to the surgeon. METHODS: Data for all patients with mammographic lesions who underwent SCNB or UCNB since their introduction at this institution were prospectively collected over 17 months. Mean inclusive costs of the three procedures were accumulated and compared. RESULTS: Stereotactic core needle biopsy was performed for 342 lesions in 319 women, for a malignancy rate of 19%; UCNB was performed for 157 lesions in 144 patients, yielding a malignancy rate of 17%. With a mean follow-up of 13.5 months, 1 patient with in situ carcinoma was diagnosed late. Absolute cost savings for the period studied was $721,963. CONCLUSIONS: Minimally invasive breast biopsy procedures can safely and reliably be performed by surgeons in clinical practice with increased patient convenience and decreased costs.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Biopsia con Aguja
/
Neoplasias de la Mama
/
Técnicas Estereotáxicas
Tipo de estudio:
Diagnostic_studies
/
Observational_studies
Límite:
Adult
/
Aged
/
Aged80
/
Female
/
Humans
/
Middle aged
Idioma:
En
Revista:
Am J Surg
Año:
1997
Tipo del documento:
Article
País de afiliación:
Estados Unidos
Pais de publicación:
Estados Unidos