Perfluoroctyl bromide as a blood pool contrast agent for computed tomographic angiography.
Fruman, S A; Harned, R K; Marcus, D; Kaufman, S; Swenson, R B; Bernardino, M E.
Afiliación
  • Fruman SA; Department of Radiology, Emory University School of Medicine, Atlanta, GA 30322, USA.
Acad Radiol ; 1(2): 151-3, 1994 Oct.
Article en En | MEDLINE | ID: mdl-9419479
ABSTRACT
RATIONALE AND

OBJECTIVES:

We determined whether perfluoroctyl bromide (perflubron) could be used as a computed tomography (CT) angiographic agent by studying vessel visibility (celiac artery, superior mesenteric artery [SMA], and renal arteries) with spiral CT and three-dimensional (3D) reconstructions.

METHODS:

Five rhesus monkeys were examined with a perflubron emulsion (90% [w/v] perfluorochemical; administered intravenously at a dose of 1.5 ml/kg and at a rate of 0.5 ml/sec. Spiral CT was performed immediately and at 5 hr after injection. Three dimensional images of the aorta at the level of the celiac artery, SMA, and renal arteries were reconstructed and blindly rated 0-4 (0 = not seen; 4 = excellent visualization) by two observers.

RESULTS:

All the vessels had the best ratings immediately after injection celiac artery, 2.8 +/- 0.42; SMA, 2.7 +/- 0.48; left renal artery, 2.1 +/- 0.99; and right renal artery, 1.2 +/- 1.03. The ratings after the 5-hr delay were as follows celiac artery, 1.3 +/- 1.34; SMA, 1.5 +/- 1.08; left renal artery, 1.5 +/- 0.97; and right renal artery, 1.2 +/- 0.79.

CONCLUSIONS:

Spiral CT angiography with a perflubron emulsion successfully demonstrated all vessels immediately and at 5 hr after contrast agent infusion. Further refinements of the dose, rate, and reconstruction technique are expected to increase vessel visibility over this wide imaging window.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Sangre / Angiografía / Tomografía Computarizada por Rayos X / Medios de Contraste / Fluorocarburos Límite: Animals Idioma: En Revista: Acad Radiol Asunto de la revista: RADIOLOGIA Año: 1994 Tipo del documento: Article País de afiliación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Sangre / Angiografía / Tomografía Computarizada por Rayos X / Medios de Contraste / Fluorocarburos Límite: Animals Idioma: En Revista: Acad Radiol Asunto de la revista: RADIOLOGIA Año: 1994 Tipo del documento: Article País de afiliación: Estados Unidos