Your browser doesn't support javascript.
loading
Effect of parasympathetic blockade on the signal-averaged electrocardiogram.
Christiansen, E H; Frøbert, O.
Afiliación
  • Christiansen EH; Department of Cardiology, Skejby Sygehus, University Hospital, Aarhus, Denmark. skejehc@aau.dk
Clin Auton Res ; 8(3): 165-71, 1998 Jun.
Article en En | MEDLINE | ID: mdl-9651666
ABSTRACT
Low parasympathetic activity is associated with late potentials detected at a noise level of 0.4 microV in a signal-averaged electrocardiogram (SAECG) following myocardial infarction. In contrast, at a noise level of 0.2 microV, lowering parasympathetic activity influences late potential parameters in the opposite direction in healthy subjects. The aim of this study was to estimate the relationship between parasympathetic activity and the SAECG obtained at noise levels of 0.4 and 0.2 microV in healthy subjects. Two SAECG recordings in 10 healthy subjects were obtained at noise levels of 0.2 and 0.4 microV before and after parasympathetic blockade using atropine (1 mg). Signal-averaged QRS duration (SA-QRS), late potential duration (LPD) defined as duration of terminal signals below 40 microV, and root mean square voltage of the terminal 40 ms of the averaged QRS (RMS40) were measured. At a noise level of 0.2 microV SA-QRS reduced from 124 +/- 14 to 114 +/- 17 ms (P = 0.008), LPD from 37 +/- 10 to 28 +/- 14 ms (P = 0.01), and RMS40 increased from 26 +/- 22 to 41 +/- 25 microV (P = 0.006) during parasympathetic blockade compared to baseline values. At a noise level of 0.4 microV the SA-QRS (115 +/- 15 ms) and LPD (29 +/- 11 ms) were lower and the RMS40 (37 +/- 23 microV) was higher compared to the noise level 0.2 microV, and no systematic alterations of the three variables were found during parasympathetic blockade. The parasympathetic nervous system may induce a very low-amplitude late potential in the SAECG. The data suggest that parasympathetic activity and a low noise level may lead to a false late potential-positive SAECG in low arrhythmia risk subjects. Therefore, we recommend the use of a noise level of 0.4 microV or identification of high arrhythmia risk patients by late potential and low parasympathetic activity.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Parasimpatolíticos / Electrocardiografía Tipo de estudio: Etiology_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Auton Res Asunto de la revista: NEUROLOGIA Año: 1998 Tipo del documento: Article País de afiliación: Dinamarca
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Parasimpatolíticos / Electrocardiografía Tipo de estudio: Etiology_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Auton Res Asunto de la revista: NEUROLOGIA Año: 1998 Tipo del documento: Article País de afiliación: Dinamarca