Bloodstream infection associated with needleless device use and the importance of infection-control practices in the home health care setting.
J Infect Dis
; 179(2): 442-8, 1999 Feb.
Article
en En
| MEDLINE
| ID: mdl-9878029
ABSTRACT
The influence of infection-control practices on bloodstream infection (BSI) risk was examined in a home health care setting in which three needleless devices were used consecutively. A case-control study and a retrospective cohort study were conducted. Risk factors for BSI included lower education level, younger age, having a central venous catheter (CVC) with multiple ports, or having a tunneled CVC. Among patients with a tunneled CVC, those at greatest risk had been allowed to shower rather than bathe and to get their exit site wet (P<.01). A high proportion (49%) of isolates were hydrophilic gram-negative bacteria, suggesting water sources of infection. In the cohort study, the BSI rate decreased as the frequency of changing the needleless device end cap increased from once weekly up to every 2 days, suggesting that the mechanism for BSI may involve contamination from the end cap. These findings may help to develop infection-control measures specific to home health care.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Infecciones Bacterianas
/
Cateterismo
/
Control de Infecciones
/
Servicios de Atención de Salud a Domicilio
/
Micosis
Tipo de estudio:
Etiology_studies
/
Incidence_studies
/
Observational_studies
/
Risk_factors_studies
Límite:
Adolescent
/
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
J Infect Dis
Año:
1999
Tipo del documento:
Article
País de afiliación:
Estados Unidos