Three Dimensional Volume Rendering Virtual Endoscopy of the Ossicles Using a Multi-Row Detector CT: Applications and Limitations
Journal of the Korean Radiological Society
; : 85-90, 2005.
Article
en Ko
| WPRIM
| ID: wpr-120202
Biblioteca responsable:
WPRO
ABSTRACT
PURPOSE: This study was conducted to know the applications and limitations of three dimensional volume rendering virtual endoscopy of the ossicles using a multi-row detector CT. MATERIALS AND METHODS: This study examined 25 patients who underwent temporal bone CT using a 16-row detector CT as a result of hearing problems or trauma. The axial CT scan of the temporal bone was performed with a 0.6 mm collimation, and a reconstruction was carried out with a U70u Sharp of kernel value, a 1 mm thickness and 0.5-1.0 mm increments. After observing the ossicles in the axial and coronal images, virtual endoscopy was performed using a three dimensional volume rendering technique with a threshold value of -500 HU. The intra-operative otoendoscopy was performed in 12 ears, and was compared with the virtual endoscopy findings. RESULTS: Virtual endoscopy of the 29 ears without hearing problems demonstrated hypoplastic or an incomplete depiction of the stapes superstructures in 25 ears and a normal depiction in 4 ears. Virtual endoscopy of 21 ears with hearing problems demonstrated no ossicles in 1 ear, no malleus in 3 ears, a malleoincudal subluxation in 6 ears, a dysplastic incus in 5 ears, an incudostapedial subluxation in 9 ears, dysplastic stapes in 2 ears, a hypoplastic or incomplete depiction of the stapes in 16 ears and no stapes in 1 ear. In contrast to the intra-operative otoendoscopy, 8 out of 12 ears showed a hypoplastic or deformed stapes in the virtual endoscopy. CONCLUSION: Volume rendering virtual endoscopy using a multi-row detector CT is an excellent method for evaluation the ossicles in three dimension, even though the partial volume effect for the stapes superstructures needs to be considered.
Palabras clave
Texto completo:
1
Base de datos:
WPRIM
Asunto principal:
Estribo
/
Hueso Temporal
/
Tomografía Computarizada por Rayos X
/
Oído
/
Endoscopía
/
Audición
/
Yunque
/
Martillo
Límite:
Humans
Idioma:
Ko
Revista:
Journal of the Korean Radiological Society
Año:
2005
Tipo del documento:
Article