Determination of schisandrin in shengmaiyin by HPLC / 中国中药杂志
China Journal of Chinese Materia Medica
; (24): 39-72, 2003.
Article
en Zh
| WPRIM
| ID: wpr-266823
Biblioteca responsable:
WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To determine the concentration of schisandrin in Shengmaiyin with HPLC.</p><p><b>METHOD</b>The sample was extracted with ethyl acetate through supersonic wave. The solution was filtrated and evaporated. The residue was resolved with methanol and determined by HPLC using PHENOMENEX C18 (4.6 mm x 250 mm, 5 microns) chromatographic column, methanol-acetonitrile-water (151510) as mobile phase. The wavelength for detection was 254 nm.</p><p><b>RESULT</b>The peak of schizandrin appears on about 7.10 minutes. The standard curves of schizandrin were linear in the concentration range of 0.2-2.0 micrograms, r = 0.9996. The average recovery of schizandrin were 100.5% (RSD 2.84%).</p><p><b>CONCLUSION</b>This method was found to be sensitive, quick and accurate for the measurement of schizandrin concentrations in Shengmaiyin.</p>
Texto completo:
1
Base de datos:
WPRIM
Asunto principal:
Plantas Medicinales
/
Compuestos Policíclicos
/
Medicamentos Herbarios Chinos
/
Química
/
Administración Oral
/
Cromatografía Líquida de Alta Presión
/
Lignanos
/
Schisandra
/
Ciclooctanos
/
Combinación de Medicamentos
Idioma:
Zh
Revista:
China Journal of Chinese Materia Medica
Año:
2003
Tipo del documento:
Article