Your browser doesn't support javascript.
loading
Analysis of reliability and validity of the Chinese version of Nijmegen Cochlear Implant Questionnaire / 中华耳鼻咽喉头颈外科杂志
Article en Zh | WPRIM | ID: wpr-336859
Biblioteca responsable: WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To investigate the reliability and validity of the Chinese version of Nijmegen Cochlear Implant Questionnaire (NCIQ).</p><p><b>METHODS</b>There were six subdomains: basic sound perception, advanced sound perception, speech production, self-esteem, activities and social Interactions. The cross-cultural adaptation measures were used to translate the NCIQ into its Chinese version. Ninety-four cochlear implant users no younger than 18 years old were included. Test-retest analysis was administered randomly to 30 users without significant changes in health and social status during a two weeks' interval between test and retest.</p><p><b>RESULTS</b>(1) Reliability: test-retest reliability of the NCIQ was proved to be satisfactory. All domains had coefficients that exceeded 0.70 (P < 0.01). Except for the subdomain, speech production, whose Cronbach's α score was 0.560, other Cronbach's α scores were greater than 0.700. (2) VALIDITY: The correlation coefficients between overall NCIQ scores and the six subdomains were 0.620 - 0.810 (P < 0.01). There were weak or no correlations among the six subdomains. The evaluation of content validity by expert review showed the questionnaire had good content validity. NCIQ total scores in postlingually deafened users were significantly higher than those in prelingually deafened users (Z = 4.350, P = 0.000). This was also true for scores of the following subdomains:advanced sound perception (Z = 4.774, P = 0.000), speech production (Z = 4.416, P = 0.000), self-esteem (Z = 3.718, P = 0.000), activities (Z = 3.228, P = 0.001) and social interactions (Z = 3.001, P = 0.003). There was no significant difference between scores obtained from the two groups in the subdomain of basic sound perception (Z = 1.943, P = 0.052).</p><p><b>CONCLUSIONS</b>The Chinese version of the NCIQ meets many psychometric criteria of a robust instrument. It possesses appropriate validity and good reliability, and can be used to measure the outcome of cochlear implant adults in China.</p>
Asunto(s)
Texto completo: 1 Base de datos: WPRIM Asunto principal: Calidad de Vida / Rehabilitación / Encuestas y Cuestionarios / Reproducibilidad de los Resultados / Implantes Cocleares / Implantación Coclear / Pueblo Asiatico / Estudios de Evaluación como Asunto / Lenguaje Tipo de estudio: Diagnostic_studies / Evaluation_studies Aspecto: Equity_inequality / Patient_preference Límite: Adolescent / Adult / Aged / Female / Humans / Male Idioma: Zh Revista: Chinese Journal of Otorhinolaryngology Head and Neck Surgery Año: 2010 Tipo del documento: Article
Texto completo: 1 Base de datos: WPRIM Asunto principal: Calidad de Vida / Rehabilitación / Encuestas y Cuestionarios / Reproducibilidad de los Resultados / Implantes Cocleares / Implantación Coclear / Pueblo Asiatico / Estudios de Evaluación como Asunto / Lenguaje Tipo de estudio: Diagnostic_studies / Evaluation_studies Aspecto: Equity_inequality / Patient_preference Límite: Adolescent / Adult / Aged / Female / Humans / Male Idioma: Zh Revista: Chinese Journal of Otorhinolaryngology Head and Neck Surgery Año: 2010 Tipo del documento: Article