Comparação e concordância de instrumentos de avaliação da amplitude de movimento da coluna cervical de homens universitários / Comparison of methods for assessing cervical range of motion in college men
Rev. educ. fis
; 24(4): 609-616, out.-dez. 2013. tab
Article
in Pt
| LILACS
| ID: lil-711190
Responsible library:
BR1.1
RESUMO
O objetivo deste estudo é comparar e analisar a concordância de três instrumentos de medidas (inclinômetro marca Lafayette, flexímetro marca Sanny e flexímetro marca Code) nos movimentos de flexão e extensão da coluna cervical. A amostra foi composta por 41 homens universitários (20,8 ± 2,2 anos, 1,78 ± 0,07 m, 57,1 ±11,3 kg). Para a análise dos dados, utilizaram-se ANOVA one-way, concordância de Bland e Atlman, análise de regressão múltipla, correlação de Spearman, adotando-se uma significância de 5%. Não houve diferenças significantes entre os valores de amplitude de movimento avaliados pelos diferentes instrumentos para a flexão (mediana=63 graus; P=0,95) e extensão da coluna cervical (mediana=73 graus; P=0,90). Para todos os instrumentos, foram observados valores de concordância, entre as análises, próximos de zero (-0,34< < 0,26). Conclui-se que os valores de amplitude de movimento não diferem entre os instrumentos, possibilitando a comparação de medidas realizadas por eles, especificamente para universitários do sexo masculino.
ABSTRACT
The purpose of the present study was to compare and analyze the concordance of three instruments (Inclinometer Lafayette, fleximeter Sanny, and fleximeter Code) in flexion and extension of cervical spine. The sample was composed by forty-one college men (20.8 ± 2.2 years, 1.78 ± 0.07 m, 57.1 ±11.3 kg). For statistical analyses ANOVA one-way, Bland and Atlman procedures, multiple regression analysis, and Spearman correlation coefficient were employed, with P< 0.05. According to the results, there were no significant differences among scores produced by the three instruments for flexion (median=63 degrees; P=0.95) and extension of cervical spine (median=73degrees; P=0.90), and concordance scores, between the analyzes, near zero (-0.34< < 0.26). The results of this study indicate that the fleximeter Code, fleximeter Sanny, and inclinometer Lafayette measurement values are consistent, which allows comparisons between themselves and using similar cutoffs, specifically for healthy male college students, in flexion and extension of cervical spine, specifically for college men.
Full text:
1
Collection:
01-internacional
Database:
LILACS
Language:
Pt
Journal:
Rev. educ. fis
Year:
2013
Document type:
Article
Affiliation country: