Your browser doesn't support javascript.
loading
Preference for Easyhaler® Over Previous Dry Powder Inhalers in Asthma Patients: Results of the DPI PREFER Observational Study.
Alvarez-Gutiérrez, Francisco Javier; Gómez-Bastero Fernández, Ana; Medina Gallardo, Juan Francisco; Campo Sien, Carlos; Rytilä, Paula; Delgado Romero, Julio.
Affiliation
  • Alvarez-Gutiérrez FJ; Unidad de Asma, Hospital Universitario Virgen del Rocio, Sevilla, Spain.
  • Gómez-Bastero Fernández A; Unidad de Asma, Hospital Universitario Virgen Macarena, Sevilla, Spain.
  • Medina Gallardo JF; Unidad de Asma, Hospital Universitario Virgen del Rocio, Sevilla, Spain.
  • Campo Sien C; Orion Pharma Iberia, Madrid, Spain.
  • Rytilä P; Orion Pharma Corporate, Espoo, Finlandia.
  • Delgado Romero J; Unidad de Gestión Clinica Alergología, Hospital Virgen Macarena, Sevilla, Spain.
Patient Prefer Adherence ; 15: 349-358, 2021.
Article in En | MEDLINE | ID: mdl-33628015
ABSTRACT

OBJECTIVE:

To study patient preference for and satisfaction with the Easyhaler® device and to assess ease of training and use of the inhaler in patients previously treated with a variety of dry powder inhalers (DPIs).

METHODS:

We designed a non-interventional, cross-sectional, single-visit observational study of adult patients with persistent asthma referred to specialized care who had previously been treated with DPI inhalers for at least 3 months. Once clinical baseline data had been checked, patients filled in questionnaires on asthma control (GINA 2019), Feeling of Satisfaction with the Inhaler (FSI-10), and adherence (TAI and Morisky-Green questionnaires). Thereafter, all patients were trained in the use of Easyhaler. We assessed ease of use and satisfaction (FSI-10) with Easyhaler, as well as inhaler device preferences.

RESULTS:

We recruited 502 patients (mean age, 50.2 ± 16.2 y; 63.1% female), of whom 485 were evaluable. In response to the main objective of the study, we compared the values of the self-completed adapted FSI-10, to measure satisfaction with the inhaler. A significantly higher score in each item of the questionnaire was recorded for Easyhaler. Overall, 38% of patients showed exclusive preference for Easyhaler (compared with 15% for the previous device) or were evenly matched in 46% of cases.

CONCLUSION:

In the present study, Easyhaler achieved better patient ratings in terms of preference and satisfaction than previously used DPI devices. In order to improve asthma adherence strategies, patient preferences and device choice should be taken into account.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Observational_studies Aspects: Patient_preference Language: En Journal: Patient Prefer Adherence Year: 2021 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Observational_studies Aspects: Patient_preference Language: En Journal: Patient Prefer Adherence Year: 2021 Document type: Article Affiliation country: