Your browser doesn't support javascript.
loading
Measurement of neuropeptide Y with molecularly imprinted polypyrrole on carbon fiber microelectrodes.
López, Luis; Lozano, Kelly; Cruz, John; Flores, Krystal; Fernández-Vega, Lauren; Cunci, Lisandro.
Affiliation
  • López L; Department of Chemistry, University of Puerto Rico - Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, PR 00931, United States.
  • Lozano K; Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, PR 00778, United States.
  • Cruz J; Department of Chemistry, University of Puerto Rico - Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, PR 00931, United States.
  • Flores K; Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, PR 00778, United States.
  • Fernández-Vega L; Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, PR 00778, United States.
  • Cunci L; Department of Chemistry, University of Puerto Rico - Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, PR 00931, United States. Electronic address: lisandro.cunci@upr.edu.
Neuropeptides ; 104: 102413, 2024 Apr.
Article in En | MEDLINE | ID: mdl-38335798
ABSTRACT
The measurement of neuropeptides using small electrodes for high spatial resolution would provide us with localized information on the release of neuromolecules. The release of Neuropeptide Y (NPY) is related to different neurological diseases such as stress, obesity, and PTSD, among others. In this conference paper, we electrodeposited polypyrrole on carbon fiber microelectrodes in the presence of NPY to develop a molecularly imprinted polypyrrole sensitive to NPY. Optimization of the electrodeposition process resulted in the full coverage of the polymer with nucleation sites on the carbon fiber ridges, achieving completion by the seventh cycle. Electrodeposition was performed for five cycles, and using cyclic voltammetry (CV), we studied the change in the oxidation current peak for polypyrrole due to the presence of NPY. We also observed a change in capacitance due to the presence of NPY, which was studied by electrochemical impedance spectroscopy (EIS). A linear correlation was found between the oxidation peak and the concentration of NPY between 50 ng/mL and 1000 ng/mL. In addition, a linear correlation was also found between microelectrode capacitance and the concentration of NPY between 50 ng/mL and 1000 ng/mL at 100 kHz.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polymers / Neuropeptide Y Language: En Journal: Neuropeptides Year: 2024 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polymers / Neuropeptide Y Language: En Journal: Neuropeptides Year: 2024 Document type: Article Affiliation country: Country of publication: