Your browser doesn't support javascript.
loading
Computed Tomography Scan Versus Saline Load Test in the Detection of Traumatic Arthrotomies of the Ankle: A Cadaveric Study.
Gheewala, Rohan A; Lakra, Akshay; Villacres Mori, Benjamin; Carroll, Jeremy D; Puleo, James M; Smith, Michael P; Mulligan, Michael T.
Affiliation
  • Gheewala RA; Department of Orthopedic Surgery, Albany Medical Center, Albany, NY; and.
  • Lakra A; Department of Orthopedic Surgery, Albany Medical Center, Albany, NY; and.
  • Villacres Mori B; Department of Orthopedic Surgery, Albany Medical Center, Albany, NY; and.
  • Carroll JD; Department of Orthopedic Surgery, Albany Medical Center, Albany, NY; and.
  • Puleo JM; Department of Orthopedic Surgery, Albany Medical Center, Albany, NY; and.
  • Smith MP; Albany Medical College, Albany, NY.
  • Mulligan MT; Department of Orthopedic Surgery, Albany Medical Center, Albany, NY; and.
J Orthop Trauma ; 38(4): 196-199, 2024 Apr 01.
Article in En | MEDLINE | ID: mdl-38442239
ABSTRACT

OBJECTIVE:

To evaluate the sensitivity and ability of computed tomography (CT) scan for diagnosing traumatic ankle arthrotomies compared with that of the saline load test (SLT).

METHODS:

Eleven cadaveric ankles were included in this study. Before intervention, a CT scan was obtained to confirm the absence of intra-articular air. Arthrotomies were created at the anterolateral, posterolateral, anteromedial, and posteromedial aspects of the ankle under fluoroscopic visualization. A postarthrotomy and postrange of motion CT scan was obtained to evaluate for the presence of intra-articular air. Each ankle then underwent a SLT with 60 mL of saline, where volumes provoking extravasation were recorded.

RESULTS:

Of the 11 included ankles, intra-articular air was detected in all 11 ankles by CT scan. All 11 ankles also demonstrated extravasation of saline through the arthrotomy site during SLT. Thus, the sensitivity for both CT scan and SLT for detecting ankle traumatic arthrotomy was 100%. The mean volume of saline needed for extravasation was 7.7 mL, with a range of 3-22 mL and a SD of 5.4.

CONCLUSIONS:

Given that CT scan was equally as sensitive to the SLT, this study presents good evidence that CT scan may be used for the detection of ankle traumatic arthrotomies.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Sodium Chloride / Ankle Limits: Humans Language: En Journal: J Orthop Trauma / J. orthop. trauma / Journal of orthopaedic trauma Journal subject: ORTOPEDIA / TRAUMATOLOGIA Year: 2024 Document type: Article Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Sodium Chloride / Ankle Limits: Humans Language: En Journal: J Orthop Trauma / J. orthop. trauma / Journal of orthopaedic trauma Journal subject: ORTOPEDIA / TRAUMATOLOGIA Year: 2024 Document type: Article Country of publication: