Your browser doesn't support javascript.
loading
[Oblique Lumbar Interbody Fusion Combined With 4-Screw Fixation for Treating Two-Level Degenerative Lumbar Diseases:A Finite Element Study].
Ge, Ting; Hu, Bai-Wen; Xiao, Jin; Zhang, Qiao-Lin; Wu, Xiao-Chuan; Xia, Dong-Dong.
Affiliation
  • Ge T; Department of Orthopedics,The First Affiliated Hospital of Ningbo University,Ningbo,Zhejiang 315010,China.
  • Hu BW; Department of Orthopedics,The First Affiliated Hospital of Ningbo University,Ningbo,Zhejiang 315010,China.
  • Xiao J; Department of Orthopedics,The First Affiliated Hospital of Ningbo University,Ningbo,Zhejiang 315010,China.
  • Zhang QL; Faculty of Sports Science,Ningbo University,Ningbo,Zhejiang 315211,China.
  • Wu XC; Department of Orthopedics,The First Affiliated Hospital of Ningbo University,Ningbo,Zhejiang 315010,China.
  • Xia DD; Department of Orthopedics,The First Affiliated Hospital of Ningbo University,Ningbo,Zhejiang 315010,China.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 46(3): 341-347, 2024 Jun.
Article in Zh | MEDLINE | ID: mdl-38953258
ABSTRACT
Objective To demonstrate the feasibility of oblique lumbar interbody fusion (OLIF) combined with 4-screw fixation for treating two-level lumbar degenerative diseases.Methods An intact finite element model of L3-S1 (M0) was constructed and validated.Then,we constructed the M1 model by simulating OLIF surgery at L3/4 and L4/5 segments on the M0 model.By attachment of posterior 4-screw or 6-screw fixation to the M1 model,three 4-screw fixation models (M2-M4) and one 6-screw fixation model (M5) were established.The segmental and overall range of motion (ROM) and the peak von Mises stresses of superior endplate,cage,and posterior screw-rod were investigated under each implanted condition.Results Under the motion modes of forward flexion,backward extension,bilateral (left and right) flexion,and left and right rotation,the L3/4 ROM of M2 model and L4/5 ROM of M3 model increased,while the L3/4 and L4/5 ROM of M4 and M5 models significantly decreased compared with those of M1 model.Under all motion modes,the L4 superior endplate in M2 model and the L5 superior endplate in M3 model showed the maximum peak von Mises stress,and the peak von Mises stresses of L4 and L5 superior endplates in M4 and M5 models were close.The L3/4 cage in M2 model and the L4/5 cage in M3 model showcased the largest peak von Mises stress,and the peak von Mises stresses of cages in M4 and M5 models were close.The peak stresses of internal fixation in M2-M5 models were close.Conclusion Four-screw fixation can replace 6-screw fixation in the OLIF surgery for treating two-level degenerative lumbar diseases.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Spinal Fusion / Bone Screws / Finite Element Analysis / Lumbar Vertebrae Limits: Humans Language: Zh Journal: Zhongguo Yi Xue Ke Xue Yuan Xue Bao Year: 2024 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Spinal Fusion / Bone Screws / Finite Element Analysis / Lumbar Vertebrae Limits: Humans Language: Zh Journal: Zhongguo Yi Xue Ke Xue Yuan Xue Bao Year: 2024 Document type: Article Affiliation country: