Your browser doesn't support javascript.
loading
Eu3+-functionalized covalent organic framework for ratiometric fluorescence detection and adsorption of tetracycline and information steganography.
Long, Qing-Hong; Hong, Li-Na; Han, Chun; Li, Xin-Yuan; Liao, Yi-Jing; Yan, Xi-Luan; Mai, Xi; Li, Na.
Affiliation
  • Long QH; School of Pharmaceutical Science, Nanchang University, Nanchang, 330006, People's Republic of China.
  • Hong LN; School of Pharmaceutical Science, Nanchang University, Nanchang, 330006, People's Republic of China.
  • Han C; Nanchang Center for Disease Control and Prevention, The Collaboration Unit for Field Epidemiology of State Key Laboratory for Infectious Disease Control and Prevention, Nanchang, Jiangxi, 330038, People's Republic of China.
  • Li XY; School of Pharmaceutical Science, Nanchang University, Nanchang, 330006, People's Republic of China.
  • Liao YJ; School of Pharmaceutical Science, Nanchang University, Nanchang, 330006, People's Republic of China.
  • Yan XL; School of Pharmaceutical Science, Nanchang University, Nanchang, 330006, People's Republic of China.
  • Mai X; School of Pharmaceutical Science, Nanchang University, Nanchang, 330006, People's Republic of China. maixi123@aliyun.com.
  • Li N; School of Pharmaceutical Science, Nanchang University, Nanchang, 330006, People's Republic of China. lin@ncu.edu.cn.
Mikrochim Acta ; 191(9): 519, 2024 08 07.
Article in En | MEDLINE | ID: mdl-39110252
ABSTRACT
Functional materials with organic/inorganic composites as the main matrix and rare earth ion complexes as the guest have shown a very broad application prospect for antibiotic sensors. However, Eu3+-complex often relies on a single fluorescence response signal, which is susceptible to changes in the detection environment and cannot simultaneously detect and remove tetracycline (TC). Herein, green fluorescent covalent two-dimensional organic framework (COF-TD) is synthesized, followed by modification of Eu3+ to synthesize COF-TD@Eu3+. In the ratiometric sensor, Eu3+ serves as the recognition site and specific response probe for TC, while COF-TD is the fluorescence reference and carrier for Eu3+. Due to the antenna effect, TC enhances the red fluorescence of Eu3+, while the green fluorescence of COF-TD remains almost stable. Based on the change of fluorescence intensity and fluorescence color from green to red, the efficient ratiometric sensing can be finished in 1 min. The developed method shows high sensitivity with a detection limit of 0.3 µM and high selectivity to TC which makes the method applicable to detect TC in traditional Chinese medicine preparations. In addition, due to the high specific surface area of COFs and specific adsorption sites, COF-TD@Eu3+ also shows good performance for TC removal. The findings show that the maximum adsorption capacity is 137.3 mg g-1 and the adsorption equilibrium is reached in 30 min. Smartphone assisted COF-TD@Eu3+ for both ratiometric fluorescence detection and detecting the absorption of TC is proposed for the first time. The molecular cryptosteganography that transforms the selective response of COF-TD@Eu3+ to binary strings is anticipated to advance utilization of nanomaterials in logic sensing and information safety.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Spectrometry, Fluorescence / Tetracycline / Europium / Limit of Detection / Fluorescent Dyes / Metal-Organic Frameworks Language: En Journal: Mikrochim Acta Year: 2024 Document type: Article Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Spectrometry, Fluorescence / Tetracycline / Europium / Limit of Detection / Fluorescent Dyes / Metal-Organic Frameworks Language: En Journal: Mikrochim Acta Year: 2024 Document type: Article Country of publication: