Your browser doesn't support javascript.
loading
[Rapid determination of polycyclic aromatic hydrocarbons and phthalates in tap water by SBSE combined with GC-MS].
Tian, Chunxia; Sheng, Yanyan; Yao, Yanhong; Zhao, Yongxin; Zhang, Nianhua.
Affiliation
  • Tian C; Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China.
  • Sheng Y; Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China.
  • Yao Y; Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China.
  • Zhao Y; Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China.
  • Zhang N; Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China.
Wei Sheng Yan Jiu ; 53(4): 646-655, 2024 Jul.
Article in Zh | MEDLINE | ID: mdl-39155235
ABSTRACT

OBJECTIVE:

To develop a method which is used for rapid determination of 16 kinds of polycyclic aromatic hydrocarbons(PAHs) and 16 kinds of phthalates(PAEs) in tap water by stirring rod adsorption extraction(SBSE) combined with gas chromatography-mass spectrometry(GC-MS).

METHODS:

The twister mixing rod coated with polydimethylsiloxane(PDMS) and ethylene glycol-polydimethylsiloxane(EG-silicone) was used to enrich analyte from 50 mL tap water. The twister mixing rod coated with EG-silicone was directly placed into the sample bottle containing 50 mL of tap water, while fixing the PDMS stir bar on the inner wall of the sample bottle and immersing it in the liquid. Add 5%(W/V) sodium chloride to the sample bottle, followed by adding 5% methanol. Stir at room temperature for 2 hours for extraction. Next, remove the mixing stick and dry its surface. The pre-prepared SBSE was analyzed by TD-GC/MS, with the optimized thermal desorption conditions desorption temperature 275 ℃, desorption time 15 min, cryofocusing temperature-40 ℃.

RESULTS:

Regression equations revealed acceptable linearity(correlation coefficients >0.986) across the working-standard range from 200-2000 ng/L for the 32 analytes. The limits of detection(LODs)were further evaluated were from 1.13-121 ng/L. With the optimized pretreatment method, the spiked recoveries of tap samples(200 and 2000 ng/L)were in the range of 62.5%-98.4% with the relative standard deviations(RSDs) of 3.5%-25.3%.

CONCLUSION:

The established method can realize the rapid detection of high throughput in the laboratory, it is simple, convenient to operate, and the extraction and analysis time is short.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Phthalic Acids / Polycyclic Aromatic Hydrocarbons / Water Pollutants, Chemical / Gas Chromatography-Mass Spectrometry Language: Zh Journal: Wei Sheng Yan Jiu Journal subject: SAUDE PUBLICA Year: 2024 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Phthalic Acids / Polycyclic Aromatic Hydrocarbons / Water Pollutants, Chemical / Gas Chromatography-Mass Spectrometry Language: Zh Journal: Wei Sheng Yan Jiu Journal subject: SAUDE PUBLICA Year: 2024 Document type: Article Affiliation country: Country of publication: