Your browser doesn't support javascript.
loading
Safety of approved MR contrast media for intravenous injection.
Runge, V M.
Affiliation
  • Runge VM; Department of Diagnostic Radiology, University of Kentucky, Lexington 40536, USA. runge@pop.uky.edu
J Magn Reson Imaging ; 12(2): 205-13, 2000 Aug.
Article de En | MEDLINE | ID: mdl-10931582
ABSTRACT
In the last 10 years, the use of intravenous contrast media in magnetic resonance (MR) has become well-established clinical practice. Contrast media provide critical additional diagnostic information in many instances. The gadolinium chelates constitute the largest group of MR contrast media and are considered to be very safe. These agents are thought to be safer than nonionic iodinated contrast agents. Unlike x-ray agents, the gadolinium chelates are not nephrotoxic. Minor adverse reactions, including nausea (1%-2% for all agents) and hives (<1% for all agents), occur in a very low percent of cases. Health care personnel should be aware of the (extremely uncommon) potential for severe anaphylactoid reactions in association with the use of MR contrast media and be prepared should complications arise. The four gadolinium chelates currently available worldwide, gadopentetate dimeglumine, gadoteridol, gadodiamide, and gadoterate meglumine, cannot be differentiated on the basis of adverse reactions. Far fewer patients have been examined to date with the two other agents that have widespread approval, mangafodipir trisodium and ferumoxides. These latter two agents are considered to be very safe but have a higher percentage of associated adverse reactions (7%-17% with mangafodipir trisodium and 15% with ferumoxides). This review discusses the safety issues involved with administration of intravenous contrast media in MR imaging, focusing on the six agents (four gadolinium chelates, one manganese chelate, and the last a large iron particle) with widespread use world-wide.
Sujet(s)
Recherche sur Google
Collection: 01-internacional Base de données: MEDLINE Sujet principal: Imagerie par résonance magnétique / Produits de contraste Langue: En Journal: J Magn Reson Imaging Sujet du journal: DIAGNOSTICO POR IMAGEM Année: 2000 Type de document: Article Pays d'affiliation: États-Unis d'Amérique
Recherche sur Google
Collection: 01-internacional Base de données: MEDLINE Sujet principal: Imagerie par résonance magnétique / Produits de contraste Langue: En Journal: J Magn Reson Imaging Sujet du journal: DIAGNOSTICO POR IMAGEM Année: 2000 Type de document: Article Pays d'affiliation: États-Unis d'Amérique