Your browser doesn't support javascript.
loading
Intracranial vascular stenosis and occlusive disease: evaluation with CT angiography, MR angiography, and digital subtraction angiography.
Bash, Suzie; Villablanca, J Pablo; Jahan, Reza; Duckwiler, Gary; Tillis, Monica; Kidwell, Chelsea; Saver, Jeffrey; Sayre, James.
Affiliation
  • Bash S; Department of Radiology, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, CA 90095, USA.
AJNR Am J Neuroradiol ; 26(5): 1012-21, 2005 May.
Article de En | MEDLINE | ID: mdl-15891154
BACKGROUND AND PURPOSE: Although digital subtraction angiography (DSA) provides excellent visualization of the intracranial vasculature, it has several limitations. Our purpose was to evaluate the ability of helical CT angiography (CTA) to help detect and quantify intracranial stenosis and occlusion compared with DSA and MR angiography (MRA). METHODS: Twenty-eight patients underwent CTA, DSA, and 3D time-of-flight (TOF) MRA for suspected cerebrovascular lesions. All three studies were performed within a 30-day period. Two readers blinded to prior estimated or calculated stenoses, patient history and clinical information examined 672 vessel segments. Lesions were categorized as normal (0-9%), mild (10-29%), moderate (30-69%), severe (70-99%), or occluded (no flow detected). DSA was the reference standard. Unblinded consensus readings were obtained for all discrepancies. RESULTS: A total of 115 diseased vessel segments were identified. After consensus interpretation, CTA revealed higher sensitivity than that of MRA for intracranial stenosis (98% versus 70%, P < .001) and occlusion (100% versus 87%, P = .02). CTA had a higher positive predictive value than that of MRA for both stenosis (93% versus 65%, P < .001) and occlusion (100% versus 59%, P < .001). CTA had a high interoperator reliability. In 6 of 28 patients (21%), all 6 with low-flow states in the posterior circulation, CTA was superior to DSA in detection of vessel patency. CONCLUSION: CTA has a higher sensitivity and positive predictive value than MRA and is recommended over TOF MRA for detection of intracranial stenosis and occlusion. CTA has a high interoperator reliability. CTA is superior to DSA in the evaluation of posterior circulation steno-occlusive disease when slow flow is present. CTA results had a significant effect on patient clinical management.
Sujet(s)

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Angiographie cérébrale / Artériosclérose intracrânienne Type d'étude: Observational_studies / Prognostic_studies / Risk_factors_studies Limites: Adult / Aged / Female / Humans / Male / Middle aged Langue: En Journal: AJNR Am J Neuroradiol Année: 2005 Type de document: Article Pays d'affiliation: États-Unis d'Amérique Pays de publication: États-Unis d'Amérique

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Angiographie cérébrale / Artériosclérose intracrânienne Type d'étude: Observational_studies / Prognostic_studies / Risk_factors_studies Limites: Adult / Aged / Female / Humans / Male / Middle aged Langue: En Journal: AJNR Am J Neuroradiol Année: 2005 Type de document: Article Pays d'affiliation: États-Unis d'Amérique Pays de publication: États-Unis d'Amérique