Your browser doesn't support javascript.
loading
Controlling the partial coalescence of a droplet on a vertically vibrated bath.
Gilet, T; Vandewalle, N; Dorbolo, S.
Affiliation
  • Gilet T; GRASP, Physics Department, University of Liège, B-4000 Liège, Belgium.
Phys Rev E Stat Nonlin Soft Matter Phys ; 76(3 Pt 2): 035302, 2007 Sep.
Article de En | MEDLINE | ID: mdl-17930296
ABSTRACT
A method is proposed to stop the cascade of partial coalescences of a droplet laid on a liquid bath. The strategy consists of vibrating the bath in the vertical direction in order to keep small droplets bouncing. Since large droplets are not able to bounce, they partially coalesce until they reach a critical size. The system behaves as a low pass filter droplets smaller than the critical size are selected. This size has been investigated as a function of the acceleration and the frequency of the bath vibration. Results suggest that the limit size for bouncing is related to the first mode of the droplet deformation.
Recherche sur Google
Collection: 01-internacional Base de données: MEDLINE Langue: En Journal: Phys Rev E Stat Nonlin Soft Matter Phys Sujet du journal: BIOFISICA / FISIOLOGIA Année: 2007 Type de document: Article Pays d'affiliation: Belgique
Recherche sur Google